Blaze EMS-2 Operating Manual
Page 45
7 Specifications
Operating Temperature Range
-10ºC to 60ºC (14ºF to 140ºF)
Storage Temperature Range
-20ºC to 80ºC (-4ºF to 176ºF)
Power Supply
8 to 30Vdc
Current Consumption
Approx. 130mA @ 12V (backlight highest setting), 50mA @12V (backlight
lowest setting)
Display
2.6” 320x240 IPS color LCD display
Minimum 600cd/m2 brightness
Sunlight readable with anti-glare coating
LED Backlight can be set to automatic or can be manually adjusted
Alarm Output
Open collector transistor switch to ground
Maximum rating 0.25A
ADC
12 bit
Dimensions
see Blaze series dimensional drawing
Enclosure
3 1/8” (80mm) ABS, black in color, front or rear mounting. Flame retardant.
Weight
Approx. 170 grams (Instrument excluding cables)
Non-volatile memory storage
100000 write cycles
RPM Inputs
RPM inputs
Range: 0-99999 RPM.
Minimum signal for stable display: 5Vpp.
Fully A/C coupled, maximum v/- 40V.
RF noise filter plus Schmitt trigger based input
Sensor Output Voltage
+5Vdc. Max 50mA
Fuel Flow Input
Fuel Flow input
RF noise filter plus Schmitt trigger based input
External pull up resistor may be required
Sensor Output Voltage
+5Vdc. Max 50mA
Thermocouples
Type
J-type, K-type and E-Type
Measurement range
EMS-2 Internal amplifier
K-Type: -100ºC to 1200ºC (-148ºF to 2192ºF)
J-Type: -100ºC to 1100ºC (-148ºF to 2012ºF)
E-Type: -100ºC to 800ºC (-148ºF to 1472ºF)
Technology
Fully cold junction compensated using a precision internal temperature
reference and built in thermocouple linearization tables
Measurement accuracy
+/- 5 degrees typical over full temperature range, subject to quality of probe
used. We recommend MGL Avionics EGT and CHT probes
Inputs
Differential, can use grounded and isolated probes
Common mode voltage range
-2V to +3V
Channels
4 using the internal electronics, 12 using the optional external RDAC
Analog Input Channels
Analog Input Channels
4 Total. With dipswitch programmable 1k5 pullup resistor
Pressure Sender Input
Pressure Sensors
VDO Resistive Sender:
The EMS-2 supports the VDO 2, 5 and 10
Bar senders. VDO pressure senders used to measure fuel pressure require
the fuel isolation kit available from VDO.
Rotax 4-20mA Sender:
The EMS-2 supports the 4-20mA pressure
sender as used in Rotax 912/914 engines.