Blaze EMS-2 Operating Manual
Page 59
10.8 Analog Channels Dipswitch settings
Use a small screwdriver to change the switch direction.
10.9 Manifold Pressure Installation (RDAC Only)
Standard polyester or silicon hosing with an inside diameter of 3-4mm is suitable as pressure hosing. For high pressure
applications the hose should be clamped onto the connector to avoid it slipping off due to expansion of the hose. For
applications where a pressure leak may prove troublesome, such as a typical engine manifold application, a restrictor
valve should be inserted into the hose so that only very little gas leakage will be present in a case of failure or if the
instrument is removed with the engine running.
In the case of the 912 and 914 Rotax engines there is a pipe connecting the two manifolds where this connection can be
made.
10.10 OAT Probe
Connect the OAT probe red wire to the EMS-2 analog input and the black or green wire to ground.
Dipswitch
Function
1
Analog Input Channel 1 Pull up resistor
(On=Enable, OFF=Disable)
2
Analog Input Channel 2 Pull up resistor
(On=Enable, OFF=Disable)
3
Analog Input Channel 3 Pull up resistor
(On=Enable, OFF=Disable)
4
Analog Input Channel 4 Pull up resistor
(On=Enable, OFF=Disable)
5
Enables a high frequency filter in the
RPM 1 signal path
(On=Enable, OFF=Disable)
6
Enables a high frequency filter in the
RPM 2 / Fuel Flow signal path
(On=Enable, OFF=Disable)