4.10 OAT (Outside Air Temperature) Setup
OAT Display:
Select to enable or disable the OAT display.
Temp Unit:
Select whether you want the OAT to be displayed in degrees Celsius (ºC) or in degrees Fahrenheit (ºF).
High Alarm:
This enables or disables the OAT high alarm.
High Alarm:
Enter the temperature threshold for when the high alarm must be activated. Any temperature above this value will activate
the alarm.
High Caution:
Enter the temperature for the high caution. This is the lower value of the upper yellow band.
Low Caution:
Enter the temperature for the low caution. This is the upper value of the lower yellow band.
Low Alarm:
This enables or disables the OAT low alarm.
Low Alarm:
Enter the temperature threshold for when the low alarm must be activated. Any temperature below this value will activate
the alarm.
OAT Cal:
During the factory calibration a factor has been determined and entered here that will give you an accurate OAT reading.
If you find this value is incorrect then adjust the calibration factor until the FLIGHT-3 OAT matches that of a precision
thermometer. Calibration can only be done in Celcius (ºC).