6 Loading factory default settings
Press and hold the left and right most soft keys simultaneously on power up to load default factory settings. The following
message will be displayed:
7 Alarm condition
If an alarm condition occurs the following will happen:
•
The item causing the alarm condition will flash on the screen
•
An alarm warning message will be displayed on the screen
•
An external alarm switch will close
The alarm warning message and switch closure will remain until any button is pressed or until the condition(s) that
activated the alarm no longer exist.
The alarm output can be used to switch an external alarm indicator. The external alarm switch is an open collector
transistor switch to ground with a maximum rating of 0.5A DC. It is possible to wire the alarm contacts of several
Stratomaster instruments in parallel should this be desired.
To avoid false activation of the alarms, the alarm function is only active 10 seconds after the instrument has powered up.
8 Cleaning
The unit should not be cleaned with any abrasive substances. The screen is very sensitive to certain cleaning materials
and should only be cleaned using a clean, damp cloth.
Warning:
The XTreme-EMS is not waterproof. Serious damage could occur if the unit is exposed
to water and/or spray jets.
Summary of Contents for XTreme - EMS
Page 23: ...XTreme EMS Operating Manual Page 23 4 3 EMS Setup...
Page 70: ...XTreme EMS Operating Manual Page 70 12 Dimensions 12 1 Front view...
Page 71: ...XTreme EMS Operating Manual Page 71 12 2 Side view Version 1 12 3 Top view Version 1...
Page 72: ...XTreme EMS Operating Manual Page 72 12 4 Side view Version 2 12 5 Top view Version 2...