background image

Network digital multimeter

See the full

instruction manual:

MGL EUMAN

, S.L.

Parque Empresarial de Argame,

 

C/Picu Castiellu, Parcelas i-1 a i-

4

 

E-33163 Argame, Morcín

 

Asturias, España, (Spain)

 - Use wet cloth and mild detergent to clean the meter; do not use abrasives or solvents.

 - Turn to OFF switch off the power when is not in use.

 - Remove the batteries to avoid damages to the meter if it will idle for a long time.

 - Using  this  appliance  in  an  environment  with  a  strong  radiated  radio-frequency 

electromagnetic field (approximately 3V/m) may influence its measuring accuracy. The 

measuring result can be strongly deviating from the actual value.

MAINTENANCE
Replacemento of batteries

WARNING

Before opening the battery cover of the meter, remove the test probes from the circuit under 

test to avoid the risk of electric shock. 
-  When the 

 symbol is displayed, the batteries should be replaced immediately.

-  Turn the range selector to OFF and remove the test wires from the input terminals.

-  Unfasten the screws and remove the battery cover.

-  Mount new batteries, replace the battery cover and fasten the screws.

Replacement of fuse

WARNING

Before opening the battery cover of the meter, remove the test probes from the circuit under 

test to avoid the risk of electric shock.

To avoid 

fi

re hazards, be sure to use the designated fuse (at rated voltage, amperage and 

blow rate)
-  Turn the range selector to OFF and remove the test leads from the input terminals.

-  Remove the protective cover and unfasten the screws.

-  Remove the rear case, pry up one end of the fuse gently and then remove the fuse from 

the clip.

-  After a new fuse is mounted, replace the rear case and fasten the screws.

Replacing test probes

Replace test leads if leads become damaged or worn.

WARNING

Use meet EN61010-031 standard, rated CAT.III 600V, or better test leads.

ACCESORIOS

1) Test probes

 1 pair

2) Test connect live

 1 unit

3) Receiver

 1 unit

4) Protective cover

 1 unit

5) Remote unit

 1 unit

6) Short operation manual

 1 unit

The meter is a portable specialized measuring instrument with a large digital LCD, as well as 

a backlight source for easy reading. The range selector designed for a single-hand operation 

makes measurement easy. Overload protection and low battery indication are provided, It 

is an ideal multi-functional instrument with scores of practical applications for professional, 

factory, school, amateur and home use.
The meter can be used to measure DC and AC voltages and currents, and resistances, teste 

circuit continuity and diodes, detect phone line mode, judge break points in cable lines, track 

the routing of cable lines, and detect network cable integrity and non-contact voltage.

SAFETY INFORMATION

WARNING

BE EXTREMELYCAREFULWHEN USING THE METER.

 lmproper use of this device can 

result in electric shock or destruction of the meter. Take all normal safety precautions and 

follow the safeguards suggested in this manual.  To exploit full functionality of the meter and 

ensure safe operation, protection provided by the instrument will be impaired if used in a 

manner not speci

fi

ed by the manufacturer.

The Auto Range Digital Multimeter (hereinafter referred to as” the meter”) complies with the 

safety requirements for electronic measuring instruments in IEC-61010-1, falls into pollution 

degree 2 and meets the over-voltage standard of CAT. III 600V.
Follow all safety and operation instructions to ensure safe use of the meter. 
With proper use and care, the meter will give you years of satisfactory service.

PRELIMINARY

-  To operate the meter, the user must observe the following normal safety rules:

1) General protection against electric shock

2) Protection of the meter against misuse

 - When the meter is received, please check whether it has been damaged during transport.

 - After being stored and delivered under harsh conditions, the meter should be checked and 

confirmed for damage

 - The test probes must be kept in good condition. Check whether the insulation of the test 

probes has been damaged and whether any wire has been exposed.

 - Using the test probes supplied can ensure safety. If required, they must be replaced with 

those of the same model or class.

DOS AND DON´TS

 - Use the right input jack, function and range. 

 - Do not take measurements beyond the protection limits indicated in the specifications.

 - Do not touch the metal tips of the test probes when connecting the meter to the circuit to 

be measured. 

 - Keep your fingers behind the probe barriers when taking a measurement with an effective 

voltage of above 60V DC or 30V AC.

 - Do not take any voltage measurement if the value between the measuring terminal and 

the ground exceeds 1000V.

 - Select the highest range if the value to be measured in the manual range is known.

 - Do not connect the meter to any voltage source while the meter is in the current, resistance, 

diode or continuity test range.

 - Disconnect the test probes from the circuit under test before turning the range selector to 

change functions.

 - Be  careful  in  that  high  voltage  pulses  at  the  test  point  may  damage  the  meter  when 

measurements are being taken on the switching power circuit of a TV set.

 - Do not measure the resistance, diode or continuity of live circuits.

 - Do not use the meter near explosive gases, steam or dirt.

 - Stop using the meter if any abnormalities or faults are noticed.

 - Do not use the meter unless its rear case is securely fastened in its original position.

 - Do not store or use the meter in areas exposed to direct sunlight, high temperatures or 

high humidity.

PRECAUTIONS

-  Do not adjust or repair the meter by attempting to remove the rear case. Such operation 

should only be performed by a technician who fully understands the meter and the electric 

shock risk involved.

-  Remove the test probes from the circuit under test before opening the battery cover of 

the meter.

-  To  avoid  any  electric  shock  caused  by  erroneous  readings,  replace  the  batteries 

immediately when the “

       

” symbol appears on the LCD.

-  To avoid fire

 

hazards, the replacement fuse must meet the specified

 

voltage and current 

ratings of F10A/500v and F200mA/1000V (quick acting).

Network digital multimeter

INSTRUCTION MANUAL

Network digital multimeter

KPS-MT480

Cód: 602250036

ENGLISH

EN

SKU: KPSMT480CBINT

APAC: 

MGL GLOBAL SOLUTIONS LTD

info.apac@mgl-intl.com

Flat 4-1, 4/F, No. 35, Section 3 Minquan 

East Road. Taipei, Taiwan.

Tel: +886 2-2508-0877

EMEA: 

MGL EUMAN S.L.

info.emea@mgl-intl.com

Parque Empresarial Argame, 33163 

Morcín. Asturias, Spain.

Tel: +34 985-08-18-70

AMERICAS: 

MGL AMERICA, LLC.

info.na@mgl-intl.com  

US East Coast:

 2810 Coliseum Centre 

Drive, Ste. 100. Charlotte, North Carolina, 

28217 USA

Tel: +1 833 533-5899

US West Coast:

 760 Challenger Street. 

Brea, California 92821 USA

Tel: +1 310-728-6220

www.mgl-intl.com

Reviews: