OPERATING  MANUAL

for the

EDS

 Model

 

D1

Electronic oxygen Delivery System

Featuring our Pulse-Demand technology

Patent Pending

R 1.7

AUDIO

D5

D10

D12

D MODES

Unit active 
at and 

abov e 
s elect ed 
pressure 

altitudes

MADE IN USA

P ATENT P ENDI NG

PULSE   UNITS

N MODE

Unit activ e at 

all pressure 
altitudes

Oxygen Inlet

O u t l e t

!

3 0

2 5

2 0

1 5

1 0

5

0

H

M

EDSMODELD1

This single person SBA oxygen delivery device is intended for
supplemental breathing while exposed to high altitudes. On
demand and up to 25 BPM, this device delivers a pulse of
supplied oxygen at the start of each inhalation phase. Higher
altitudes are automatically compensated with larger pulses.

AIRCRAFT PILOTS SHOULD REFER TO FAR 23.1447

CONSULT MANUAL FOR PROPER DEVICE USAGE

DEVICE WILL NOT OPERATE PROPERLY UNLESS SPECIFIED

CANNULAS, FACE MASKS & REGULATORS ARE USED

Not intended for SCBA, SCUBA or MEDICAL use

M

o

u

n

ta

in

Hig

h E&S

C

o.

U

S

A

MH

Aviation

Oxygen Systems

Since 1985

8

0

0

-

4

6

8-

81

8

5 •

M

H

o

x

yg

en

.c

om

5

4

1-

92

3

-

4

1

0

0

Summary of Contents for EDS-D1

Page 1: ...evice is intended for supplemental breathing while exposed to high altitudes On demand and up to 25 BPM this device delivers a pulse of supplied oxygen at the start of each inhalation phase Higher alt...

Page 2: ...n High E S Company assumes no responsibly for any accidents injury or death that may result from the misuse of this device equipment This includes any usage of this device equipment outside the scope...

Page 3: ...g tests are showing that 90 of the oxygen the EDS D1 provides to the lungs goes directly into the blood The EDS D1 synchronous inhalation pulse demand technique is currently the most efficient way kno...

Page 4: ...hing in while pushing door outwards fig 1 This is best done if the unit is held with the battery door facing up at you and out The EDS D1 unit uses a standard 9 nine volt alkaline battery connector sy...

Page 5: ...Positive GRN RED indicators for FLOW NO FLOW oxygen delivery status Provides Apnea alarm to inform user of kinked pinched disconnected lines or holding breath too long Saves existing oxygen supply by...

Page 6: ...10 000 ft 3 0 2 5 2 0 1 5 1 0 5 0 PRESS ALT X 1K PULSE UNITS D 5 D 1 0 D 1 2 D Modes Unit delays activation until at and above selected pressure altitudes D12 Switch as seen in one of the Day or Delay...

Page 7: ...r for use with regulators that are flow rate adjustable F MODES Floor Face Mask These next four settings deserve your attention The F Mode settings are F10 F15 F20 and F25 called the floor or facemask...

Page 8: ...negative and the outside ring is positive A reverse polarity diode 1 A in the EDS unit helps prevent damage from accidental short term reverse voltage occurrences Misc notes The EDS model D1 has a bas...

Page 9: ...itially off turn on the cylinder valve slowly to allow gas from the regulator to back charge the outlet side of the EDS D1 unit Next turn the EDS D1 unit on During the time the EDS D1 unit initializes...

Page 10: ...r normal operating conditions Storage Approx 4 6 months while in the off setting battery drain is about 1 a in the off setting Make sure that the battery is removed from the unit during long term stor...

Page 11: ...r for use with an EDS unit NOTICE IMPORTANT EDS INLET PRESSURE NOTICE If The EDS D1 unit s will not be used with the XCR XCP micro lite system or EDS STR regulator the alternate regulator must be able...

Page 12: ...s and capability never offered before Complete single and multi place carry on EDS system packages are available along with padded fabric carry strap down harnesses for most of our kevlar fiber and al...

Reviews: