3. Display and button functions

3.5 Abnormal, Trip, Test and Check functions

3.5.1 Abnormal display descriptions

During abnormality, 

the display will switch back to the main display

The Phase Number 

will flash when abnormality is detected

(Setting: OVER FLASH=YES)

L1, L2 detected abnormality (Overvoltage)

The detected fault (Overvoltage) LED and 

Trip LED will flash

.

3.5.2 Triping display descriptions

After trip, if the fault is clear, 
the display will switch to memory record page

Trip memory record display
Refer to 3.4

Latest trip record memory

Record LED indicates it is in 
Record memory page

Present status
Trip LED indicates the relay had trip
Overvoltage LED indicates Overvoltage fault

3.5.3 Test and Reset function 

Normal status:
Press 

the display will show ' PRESS TEST AGAIN TO CONFIRM'

TEST

TEST

Press 

again to trip the relay, the display will show ' TEST OK' 

Trip status:
Press 

to reset the relay to normal status, the display will show ' RST TEST TRIP'

RESET

RESET BUTTON

TEST BUTTON

3.5.4 Check function description

CHECK

1. Press 

button to check the setting of the relay ( Refer to 3.2 for detail)

RECORD

Press 

button to check the record memory of the relay ( Refer to 3.2 for detail)

Long Press of either 

or 

will return back to main display

CHECK

RECORD

2. If no button is press for 3 mins, the display will automatically toggles between the 

CHECK and RECORD (CHECK and RECORD LED on respectively and show its content.

OUV400

OUV400

OUV400

OVER & UNDER VOL

T

AGE RELA

Y

L12     :     380   V

L23     :     380   V

LAST TRIP.       OU123

L12 : 168%          00 

Summary of Contents for OUV-400

Page 1: ...Mun hean singapore Pte Ltd RELAY STATUS PROG CHECK FUNCTION PROGRAM CHECK RECORD TRIP RECORD RESET TEST OPERATION MANUAL OUV400 OVER VOLTAGE UNDER VOLTAGE 01 2021 L12 380 V L23 380 V OVER UNDER VOLTAG...

Page 2: ...Indicators Program Programming mode Check Display of setting Record Display of memory records Type of Fault indicator Over Voltage Under Voltage Trip status indicator Function buttons Test and Reset...

Page 3: ...3 2 Long press to return to the numeric display screen Enter the setting main menu refer to 4 1 Trip test function keys Normal Non trip condition Press once to show PRESS TEST AGAIN TO CONFIRM Press...

Page 4: ...t U V CLEAR DELAY 97 0 100 OV Reset level setting Delay time sec U V LO LIMIT 000 UV non operating zone setting RTC YYYY MM DD 09 06 2020 RTC Real Time Clock setting Available for model wtih RTC RTC R...

Page 5: ...oltage setting Over Voltage threshold setting at 105 Over Voltage contact operation setting AUTO Auto reset CHECK mode ON indication O V CLEAR DELAY O V Over Voltage setting Over Voltage Reset value s...

Page 6: ...Trip memory record display Refer to 3 4 Latest trip record memory Record LED indicates it is in Record memory page Present status Trip LED indicates the relay had trip Overvoltage LED indicates Overv...

Page 7: ...E RELAY OVER UNDER VOLTAGE RELAY OVER UNDER VOLTAGE RELAY OVER UNDER VOLTAGE RELAY Over Voltage Under Voltage OUV400 Over Voltage Under Voltage OUV400 Over Voltage Under Voltage OUV400 Over Voltage Un...

Page 8: ...ncrease speed Value decrease long press to increase speed Confirm setting and return to sub menu U V Setting main menu Range Trip 70 100 Relay OFF AUTO LATCH U V Trip and Relay setting Enter into valu...

Page 9: ...sub menu Enter into value setting digit flashing Value increase long press to increase speed Value decrease long press to increase speed Confirm setting and return to sub menu Over thershold Flashing...

Page 10: ...f full scale Time accuracy 3 of trip time or 20ms Whichever is greater 10 Tripping Relay overvoltage Contact 1c 250Vac 5A undervoltage Contact 1a 250Vac 5A 11 LCD indication 16 x 2 display Real time 3...

Page 11: ...Start Address Lo Number of Word Lo Number of Word Hi Error Check End of Frame 01H FFH 03H 0 nnH 1 nnH CRC Lo CRC Hi 0 nnH 0H 1 Byte 2 Bytes 1 Byte 2 Bytes 2 Bytes Response no error received Start of F...

Page 12: ...x22 0xe2 0xe3 0x23 0xe1 0x21 0x20 0xe0 0xa0 0x60 0x61 0xa1 0x63 0xa3 0xa2 0x62 0x66 0xa6 0xa7 0x67 0xa5 0x65 0x64 0xa4 0x6c 0xac 0xad 0x6d 0xaf 0x6f 0x6e 0xae 0xaa 0x6a 0x6b 0xab 0x69 0xa9 0xa8 0x68 0...

Page 13: ...12 1 31 0 23 0 59 0 59 0 100 1 12 1 31 0 23 0 59 0 59 6 8 Data register Integer format Setting parameter Address Hex Contents Format Word Access Range Unit 0000 0001 0002 0003 0004 0005 0006 0007 000...

Page 14: ...2 L2 L3 4 L3 L1 Multiple phase tripping is possible If reading is 3 2 1 it will indicate that L1 L2 and L2 L3 are having fault 0 Nil 1 L1 L2 2 L2 L3 4 L3 L1 8 Test 0 Nil 1 L1 L2 UV 2 L2 L3 UV 4 L3 L1...

Reviews: