WIRING THE AUDIO OUTPUT

On the 3.5mm Plug, (not provided) the Tip is the first 

Audio Output, the Ring is the second Audio Output, 

and the Barrel is the Shield or Ground. There is no 

need to designate Left or Right as both Audio Out-

puts provide the same signal.

OPTIONAL 3.5MM STEREO AUDIO PLUG AND CABLE

To EDS 

Audio Jack

To Aircraft

TYPICAL COMMUNICATIONS WIRING

The standard wiring option has one Audio Out-

put wired to the Left Input and the other Audio 

Output wired to the Right Input. 

EDS Audio Cable

Aircraft Input

TWO O2D2-2G UNITS DRIVING ONE INPUT

The outputs from one O2D2-2G  

May NOT 

be tied to the outputs 

from another O2D2-2G. In the case 

of installing two O2D2-2G units in 

an aircraft, each should be given its 

own input to the communications 

system. If this is not an option, 

then wire the Audio Output of one 

O2D2-2G to the Left Input and the Audio 

Output of the other O2D2-2G to the Right 

Input. 

EDS Audio Cables

Aircraft Input

DRIVING A LOW IMPEDANCE INPUT

The Audio Outputs of an O2D2-2G are designed to 

drive standard stereo inputs with impedance from 

1000

Ω

 to 10,0000

Ω

. To accommodate a lower 

impedance input, parallel both Audio Outputs

EDS Audio Cable

Aircraft Input

Summary of Contents for Pulse-Demand EDS O2D2-2G

Page 1: ...atents Pending 800 468 8185 541 923 4100 Fax 541 923 4141 www MHoxygen com 2244 SE Airport Way Suite 100 Redmond OR 97756 7537 THE EDS O2D2 2GTM IS DESIGNED FOR EASY OPERATION CAREFULLY READ THIS INST...

Page 2: ...hly oxidizing gas and can vigorously accelerate combustion It can provide a catalyst for spontaneous combus tion resulting in personal injury or death if not used properly and with caution DO NOT use...

Page 3: ...he O2D2 with a Mountain High four port regulator FPR locate the oxygen input tube clear tube with a short red tube on one end and insert the Red tube into the Red Oxygen In connector on the O2D2 unit...

Page 4: ...ries should be part of your pre flight inventory Regardless of use replace batteries annually DO NOT STORE THE EDS UNIT WHILE THE INLET IS UNDER PRESSURE Remove all sources of oxygen pressure and secu...

Page 5: ...lthy person using a cannula at the given altitudes your needs may be different To determine whether you are receiving enough oxygen in a particular mode you will need to use a pulse oximeter available...

Page 6: ...LOW FAULT EVENT The LED Red Light will flash on and off along with a Hi Lo audio chime for 2 seconds with every event NOTE The FLOW FAULT is not intended as a low or out of oxygen warning It is only i...

Page 7: ...ously and leak oxygen To use the MH EDS O2D2 2G with a third party regulator or built in oxygen system with a pressure higher than 20 psi it is mandatory that you use the MH EDS IN LINE REGULATOR EDS...

Page 8: ...ower Supply with the MH EDS O2D2 2G as other power supplies may not be compatible External 4 5 VDC Power Connector The MyGoFlightAdapter DualMicro is the top of the line DC charger for 12 28 volt syst...

Page 9: ...2 2G unit against defects in materials and workmanship for two 2 years from date of purchase invoice The warranty is non transferable Should any part of the MH EDS O2D2 2G become defective within the...

Page 10: ...to ensure your system is operating properly and upgraded to the latest specifications Any other parts replaced due to damage or field use would be subject to an additional charge Q How long should I e...

Page 11: ...as the amount of dissolved CO2 reduces in the blood so does the need to respirate Unfortunately this also exacerbates hypoxia as less oxygen is inhaled and admitted into the blood as the body has no r...

Page 12: ...EDS Audio Cable Aircraft Input TWO O2D2 2G UNITS DRIVING ONE INPUT The outputs from one O2D2 2G May NOT be tied to the outputs from another O2D2 2G In the case of installing two O2D2 2G units in an ai...

Page 13: ...r we breathe to compensate for either a deficiency on the part of the individual or a de ficiency in the atmosphere in which we are breathing A person may have a respiratory or circulatory impairment...

Page 14: ...c effects during the period in which oxygen is being used Because of the insidious nature of hypoxia a person already mildly hypoxic is very unlikely to even think of using oxygen equipment either int...

Page 15: ...en Systems Transfillers Face Masks with and without mics AMSKM 2100 02 medium with mike Anti Bacterial Face Mask Wipes 00VEN 0077 00 EZ Breathe Quick Disconnect 19053 0009 00 Cylinders E Z Breathe Can...

Page 16: ...ries are used Remove during long term storage External Power 4 5 VDC external power jack with auto battery disconnect with series diode is provided No over voltage protection is provided External Audi...

Reviews: