The patented MH EDS O2D2-2G (O2D2) is a one or two-user aviation oxygen delivery device. It is designed to deliver aviation 
oxygen in the most efficient, comfortable and convenient way possible.  With its user-selectable settings, apnea alarm and 
small size, the O2D2 is the most portable and flexible electronic digital oxygen delivery system in the world. 

By providing a measured pulse of oxygen at the beginning of each inhalation, the O2D2 supplies the oxygen you need to 
stay alert and comfortable while flying.  In contrast to constant flow systems that deliver more oxygen than the body needs, 
the O2D2 provides a short, measured pulse as you inhale. This efficient patented delivery technology ensures that you get 
the proper amount of oxygen (according to your breathing rate and physiological needs), at your altitude to stay safe and 
comfortable. It also promises a dramatic increase in cylinder duration, which enables you to enjoy the benefits of oxygen 
use below the mandated altitude. This means fewer headaches, less fatigue and better alertness when flying at night or long 
distances, enabling you to fly longer between refills, save weight, as well as space with a smaller cylinder!
 
The programmability of the O2D2 means that, unlike constant-flow oxygen systems, you can “set it and forget it”. By auto-
matically detecting your pressure altitude, the O2D2 can be set to start providing oxygen immediately or at a specified altitude 
and will automatically adjust the oxygen flow as your altitude changes.  

When you’re flying, you have more important 

things to do than adjust your oxygen flow during altitude changes?

BASIC SAFETY

Pure oxygen is a highly oxidizing gas and can vigorously accelerate combustion.  It can provide a catalyst for spontaneous combus-

tion resulting in personal injury or death if not used properly and with caution.  

DO NOT use any type of oil or grease on 

any of the fittings, valves or cylinders.  DO NOT smoke while in use. DO NOT operate near an open flame.            
         Use only approved MH External Power Supply with the O2D2-2G as the voltages are not compatible.

2

PILOT

 

#1 Blue 

6 mm 

 

outlet connects to 

Pilot cannula or face mask

Audio port

. On the bottom. 

Sound from flow-fault and 

apnea alarm conditions only.

Static ports,

 

DO NOT 

COVER

External 4.5 VDC 

Power Connector

 

On the bottom. 

See Page 8

Red 

4 mm inlet 

connects to the 

regulator

Power On/Off

 and 

Rotary 

Mode-Selector Switc

h

#2 Blue 

6 mm

 

outlet

 connects to User #2

cannula or face mask

Red/Green LED

 

indicator for 

User 1 (Pilot)

Red/Green 

LED

 indicator 

for User 2

Static ports

DO NOT 

COVER

Mounting 

Rings

Low Battery Warning

FEATURES

INTRODUCTION

 

•  Easy-to-use, small size and light weight.

 

•  Incorporates a MIL spec ruggedized easy-to-grip rotary control switch providing improved reliability, increased ease of function 

 

    and visibility. This switch also has very positive position detents for excellent tactile feedback making it resistant to changes from 

 

    casual rubbing or bumping.

 

•  Automatically adjusts oxygen flow for altitude pressure density.

 

•  Provides reduced oxygen consumption through more efficient oxygen delivery than standard constant-flow systems.

 

•  Rotary Mode-Selector Switch allows automatic altitude enable, Night and Day operations and high flow settings.

 

•  Green/Yellow/Red LED’s indicate oxygen flow, alarm, and status.
• Audible and visible flow-fault alarm informs user of kinked, pinched, or disconnected oxygen lines, obstructed cannula or mask.

 

• 

Reduced dry mouth and sinus discomfort compared to constant-flow oxygen systems.

Summary of Contents for Pulse-Demand EDS O2D2-2G

Page 1: ...atents Pending 800 468 8185 541 923 4100 Fax 541 923 4141 www MHoxygen com 2244 SE Airport Way Suite 100 Redmond OR 97756 7537 THE EDS O2D2 2GTM IS DESIGNED FOR EASY OPERATION CAREFULLY READ THIS INST...

Page 2: ...hly oxidizing gas and can vigorously accelerate combustion It can provide a catalyst for spontaneous combus tion resulting in personal injury or death if not used properly and with caution DO NOT use...

Page 3: ...he O2D2 with a Mountain High four port regulator FPR locate the oxygen input tube clear tube with a short red tube on one end and insert the Red tube into the Red Oxygen In connector on the O2D2 unit...

Page 4: ...ries should be part of your pre flight inventory Regardless of use replace batteries annually DO NOT STORE THE EDS UNIT WHILE THE INLET IS UNDER PRESSURE Remove all sources of oxygen pressure and secu...

Page 5: ...lthy person using a cannula at the given altitudes your needs may be different To determine whether you are receiving enough oxygen in a particular mode you will need to use a pulse oximeter available...

Page 6: ...LOW FAULT EVENT The LED Red Light will flash on and off along with a Hi Lo audio chime for 2 seconds with every event NOTE The FLOW FAULT is not intended as a low or out of oxygen warning It is only i...

Page 7: ...ously and leak oxygen To use the MH EDS O2D2 2G with a third party regulator or built in oxygen system with a pressure higher than 20 psi it is mandatory that you use the MH EDS IN LINE REGULATOR EDS...

Page 8: ...ower Supply with the MH EDS O2D2 2G as other power supplies may not be compatible External 4 5 VDC Power Connector The MyGoFlightAdapter DualMicro is the top of the line DC charger for 12 28 volt syst...

Page 9: ...2 2G unit against defects in materials and workmanship for two 2 years from date of purchase invoice The warranty is non transferable Should any part of the MH EDS O2D2 2G become defective within the...

Page 10: ...to ensure your system is operating properly and upgraded to the latest specifications Any other parts replaced due to damage or field use would be subject to an additional charge Q How long should I e...

Page 11: ...as the amount of dissolved CO2 reduces in the blood so does the need to respirate Unfortunately this also exacerbates hypoxia as less oxygen is inhaled and admitted into the blood as the body has no r...

Page 12: ...EDS Audio Cable Aircraft Input TWO O2D2 2G UNITS DRIVING ONE INPUT The outputs from one O2D2 2G May NOT be tied to the outputs from another O2D2 2G In the case of installing two O2D2 2G units in an ai...

Page 13: ...r we breathe to compensate for either a deficiency on the part of the individual or a de ficiency in the atmosphere in which we are breathing A person may have a respiratory or circulatory impairment...

Page 14: ...c effects during the period in which oxygen is being used Because of the insidious nature of hypoxia a person already mildly hypoxic is very unlikely to even think of using oxygen equipment either int...

Page 15: ...en Systems Transfillers Face Masks with and without mics AMSKM 2100 02 medium with mike Anti Bacterial Face Mask Wipes 00VEN 0077 00 EZ Breathe Quick Disconnect 19053 0009 00 Cylinders E Z Breathe Can...

Page 16: ...ries are used Remove during long term storage External Power 4 5 VDC external power jack with auto battery disconnect with series diode is provided No over voltage protection is provided External Audi...

Reviews: