RYZ
ELECTRICAL SYSTEM 6-11
6
ALTERING THE PULSES PER WHEEL TURN
Once the unit of measurement has been selected ( it appears fl as-
hing), press the mode button for 3 seconds. It will then be possible
to alter the number of pulses for the wheel.
This parameter expresses the number of pulses which the elec-
tronic sensor sends to the instrument panel for every turn of the
wheel.
This information is stored in memory.
ALTERING THE IMPULSES FOR EVERY ENGINE
REVOLUTION
Once the alteration made in the previous screen is completed, the
button must be held down for 3 seconds, and then it will be possi-
ble to alter the number of pulses for every engine revolution.
This parameter expresses the number of pulses for each revolu-
tion of the engine’s primary drive shaft that the machine is able to
send to the instrument panel.
This screen can be distinguished from the previous one by having
the logo “RPM”.
This information is stored in memory.
CAUTION:
• Regulating interval: from 1,000 mm to 2,500 mm with
intervals of 1 mm.
• Once the regulating menu has been accessed:
- if 20 seconds go past without the button being pressed, or
- if the machine is started up, or
- if the key switch is turned to the OFF position, the sys-
tem will automatically return to standard operating mode,
and the changes made will be lost.
CAUTION:
• Regulating interval: from 1,000 mm to 2,500 mm with
intervals of 1 mm.
• Once the regulating menu has been accessed:
- if 20 seconds go past without the button being pressed, or
- if the machine is started up, or
- if the key switch is turned to the OFF position, the sys-
tem will automatically return to standard operating mode,
and the changes made will be lost.
Summary of Contents for RYZ 50 Cross C
Page 4: ...RYZ NOTES...
Page 6: ...RYZ NOTES...
Page 10: ...RYZ NOTES...
Page 38: ...RYZ NOTES...
Page 82: ...RYZ NOTES...
Page 90: ...RYZ NOTES...
Page 91: ......