8
87D0174
SSTB11 Woodburning Fireplace
FIREPLACE LOCATION
This fireplace does not weigh more than large pieces of furniture and can normally
be located near a load bearing wall without requiring additional foundations or sup-
ports. If however, the fireplace is to be trimmed with a heavy stone or brick facing
and hearth extension, be sure the supporting structure is adequate.
Figures 3 and 4
provide dimensional details of the fireplace, required spacing to
combustible walls, and some suggested fireplace locations. When selecting a loca-
tion, choose one that is away from frequently opened doors, central heat outlets or
returns, or other places where air movements may disturb the airflow around the
fireplace. Air turbulence near the fireplace may cause smoke to spill out of the fireplace opening.
CAUTION
Do not install fireplace
over carpeting.
&0
FIREPLACELOCATION
16”
3/4”
2
6M
” Min.
60”
3/4”
8”
Model H1652
Hearth Extension
Model H1652
Hearth Extension
Parallel
Back Wall
Perpendicular
Side Wall
Side Brick Outline
Glass Door
Glass Door
Min. Air
Space
Min. Air Space
FP2179
Figure 3
&0
FIREPLACELOCATIONS
Top Views
Parallel Walls
‘Y’ Type Walls
‘T’ Type Walls
‘L’ Type Walls
‘C’ Type Walls
‘H’ Type Walls
FP2180
Figure 4