background image

Tel: 

+353 46 95 58030

Fax:

 

+353 46 95 58034

Email:

 

sales@miflues.ie

Web:

 

www. miflues.ie

SYSTEM 39

Single Wall 304 

Grade Stainless Steel

Connecting and 

Relining Flue Pipe

Summary of Contents for SYSTEM 39

Page 1: ...Tel 353 46 95 58030 Fax 353 46 95 58034 Email sales miflues ie Web www miflues ie SYSTEM 39 Single Wall 304 Grade Stainless Steel Connecting and Relining Flue Pipe ...

Page 2: ...pe and rigid chimney liner INSTALLATION 1 Select the components required for installation 2 Ensure the male end of the liner chimney system always points downwards in the direction of the heating appliance 3 Align the locating dimple and twist lock dimple on the male end of the chimney liner system with the locating dimple and receiver on the female end of the chimney system as shown below 4 Firml...

Page 3: ...340 490 Sys 39 150 340 490 Sys 39 180 340 490 Sys 39 200 340 490 Adjustable lengths are available to assist achieving the exact length required where a standard length is not suitable Adjust the pipe to the required length and secure directly above the overlap joint using a support bracket The joint is sealed using Mi Flues high temperature sealant rated to 1000 C or a suitable fire cement Caution...

Page 4: ...ART OFF Product A B Sys 39 100 85 Sys 39 125 85 Sys 39 150 85 Sys 39 180 85 Sys 39 200 85 ADAPTOR REDUCING Tapered Mi Flues System 39 Single Wall Stainless Steel Chimney STORM COWL The Storm Cowl offers the greatest protection against rain and adverse weather conditions It reduces the possibility of wind affecting the appliance It can be used on oil fired appliances It should be secured in positio...

Page 5: ... 205 250 529 Sys 39 125 230 250 545 Sys 39 150 276 305 564 Sys 39 180 322 356 764 Sys 39 200 369 405 919 Sys 39 ECONOMY WALL BRACKET Product A B C Sys 39 100 350 592 Sys 39 125 457 751 Sys 39 150 457 751 Sys 39 180 490 795 Sys 39 200 560 900 Dia A B 100 250 125 250 150 250 The Economy Wall Bracket provides lateral support The T piece is fixed to the wall with fittings adequate for the purpose The ...

Page 6: ...lled and maintained correctly Mi Flues System 39 should provide many years service and is provided with a 10 year conditional life expectancy Mi Flues System 39 Single Wall Stainless Steel Chimney Mi Flues Ltd Summerhill Enterprise Centre Summerhill County Meath IRELAND Telephone 353 46 95 58030 Fax 353 46 95 58034 Email sales miflues ie Website www miflues ie All flue systems must be installed ac...

Reviews: