Technical data: 

 

Max. Power consumption: 165W 

 

Dimensions: 51x100cm 

 

Heat emission surface: approx. 45x80cm 

 

Heating element: Carbon heating foil 

 

Three heating levels 

 

Surface temperature: High approx. 60°C, Mid approx. 45°C, Low approx. 40°C 

 

Surface material: textile 

 

Automatic safety switch-off: after 3 hours of operation or after falling over 

 

Protection class II 

 

IP protection class: IP21 

 

Cable length connection cable 1.5m 

 

Important notes before commissioning: 

 

The heating panel may emit production-related odours during initial operation. The odours 
subside or disappear after a few hours of operation. 

 

The integrated anti-tilt switch prevents the heating panel from being switched on if it is lying 
down or has not been set up vertically. 

 

 

Summary of Contents for MI-FH-51110

Page 1: ...Heizstufen Oberflächentemperatur High ca 60 C Mid ca 45 C Low ca 40 C Oberflächenmaterial Textil Automatische Sicherheits Abschaltung nach 3 Stunden Betrieb oder Umfallen Schutzklasse II IP Schutzart IP21 Kabellänge Anschlusskabel 1 5m Wichtige Hinweise vor Inbetriebnahme Das Heizpaneel gibt ggf bei der Erstinbetriebnahme produktionsbedingte Gerüche ab Die Gerüche lassen nach einigen Stunden Betri...

Page 2: ...tzen Gegenstände in bzw durch das Heizpaneel gesteckt werden Das Heizpaneel darf nicht im zusammengefalteten Zustand in Betrieb genommen werden Hilfsbedürftige Personen Kinder und temperaturempfindliche Menschen dürfen das Produkt nur unter Aufsicht benutzen Das Produkt ist von Feuer fernzuhalten und darf nicht in Kombination mit anderen Heizprodukten genutzt werden Das Produkt ist sofort außer Be...

Page 3: ...rwendet werden Der Hersteller übernimmt keinerlei Verantwortung bei falschem Gebrauch der durch Nichtbeachtung der Gebrauchsanleitung zustande kommt Technische Änderungen und Irrtümer vorbehalten Verwendung Aufstellen WICHTIG Es ist zu beachten dass sich das Heizpaneel nur einschalten lässt wenn dieses wie folgt abgebildet aufgestellt wurde Der integrierte Kippschutzschalter verhindert das Einscha...

Page 4: ...l von der Stromversorgung trennen 2 Abwarten bis das Heizpaneel vollständig abgekühlt ist 3 Das Heizpaneel darf lediglich mit einem leicht angefeuchteten Tuch oder einer weichen Bürste gereinigt werden Vor der erneuten Inbetriebnahme muss das Heizpaneel vollständig getrocknet sein 4 Die Steuereinheit sowie Kabel dürfen lediglich mit einem trockenen und weichen Tuch gereinigt werden WICHTIG Es darf...

Page 5: ...5 Abmessungen ...

Page 6: ...65 EU der EMV Richtlinie 2014 30 EU und der Niederspannungsrichtlinie 2014 35 EU befindet Die ausführliche Konformitätserklärung finden Sie unter https infrarot fussboden de Downloads_1 Dokumentation 2021 Mi Heat Heizsysteme GmbH Alle Rechte vorbehalten Ohne schriftliche Zustimmung des Herausgebers darf diese Anleitung auch nicht auszugsweise in irgendeiner Form reproduziert oder vervielfältigt we...

Page 7: ...emperature High approx 60 C Mid approx 45 C Low approx 40 C Surface material textile Automatic safety switch off after 3 hours of operation or after falling over Protection class II IP protection class IP21 Cable length connection cable 1 5m Important notes before commissioning The heating panel may emit production related odours during initial operation The odours subside or disappear after a few...

Page 8: ...combination with other heating products The product must be taken out of service immediately if it becomes wet Dry it with a cloth The product must not be washed in a washing machine The product may only be cleaned with a damp towel The heating panel must not be connected during cleaning Replacing the control unit is not permitted The Euro mains plug should never be touched with wet hands The unit...

Page 9: ...lying down or has not been placed vertically Switch on off Plug the Euro mains plug into a suitable socket All LEDs light up once briefly The heating panel is now ready for operation Press the power button to switch on the heating panel After switching on the Power and High LEDs light up To switch off the heating panel press the power button again It is recommended to disconnect the mains plug aft...

Page 10: ...n completely 3 The heating panel may only be cleaned with a slightly damp cloth or a soft brush The heating panel must be completely dry before it is used again 4 The control unit and cables may only be cleaned with a dry and soft cloth IMPORTANT No moisture may penetrate the control unit or the cable The heating panel must not be immersed in water or other liquids No cleaning agents solvents or s...

Page 11: ...11 Dimensions ...

Page 12: ...51110 is in compliance with the RoHS Directive 2011 65 EU the EMC Directive 2014 30 EU and the Low Voltage Directive 2014 35 EU The detailed Declaration of Conformity can be found at https infrarot fussboden de Downloads_1 Documentation 2021 Mi Heat Heizsysteme GmbH All rights reserved No part of this manual may be reproduced in any form or by any means without the written permission of the publis...

Reviews: