M
‑
I SWACO
MONGOOSE PRO Shale Shaker
4
Field Installation and Operation Manual 9092F02001AENG (D)
4
5.2
Variations Among MONGOOSE PRO Configurations
M
‑
I SWACO offers a variety of MONGOOSE PRO configurations; this content will help operators become
familiar with the particular model they will be using. Below is a configuration overview.
•
Shaker with Header Box
o
The fluid distribution system is at the rear of the shaker basket and is mounted above the screen deck
(Refer to Figure 2).
o
Fluid is redirected from the inlet line through the header box into a half pipe at the rear of the basket.
Since fluid distribution is mounted above the screen deck, no trap exists to collect solids. As fluid passes
through the diverter box, it sweeps the box clean.
Figure 2. MONGOOSE PRO with Carbon Steel Header Box
•
Shaker with Possum Belly with Butterfly Valve Bypass
o
The manually-adjustable butterfly valve is located below the main inlet on the possum belly (Refer to
o
When the valve is closed, fluid flow is directed through the possum belly to the shaker bed.
o
The butterfly valve bypass is opened by rotating the valve 90°. When butterfly valve is opened, fluid is
redirected into the skid, bypassing the screens.
Figure 3. MONGOOSE PRO with Butterfly Valve Possum Belly