16
Stationary Electric Air Compressor Manual
START-UP:
1. Read safety warnings before performing operation.
2. Turn the unit by applying power to the unit.
3. If you notice any unusual noise or vibration, stop the air compressor and refer to "Troubleshooting".
DUPLEX OPERATION:
CAM switch option (pump 1, Alternate , pump 2).
1. Function:
Pump 1- pump 1 will lead and begin pumping every time the tank pressure falls below 140 psi. Pump 2
will lag and begin pumping once the tank pressure is below 110 psi.
Alternate- pump1 and pump 2 will alternate which pump leads and lags. When the pressure drops below
set pressures (140/110 psi).
Pump 2- pump 2 will lead and begin pumping every time the tank pressure falls below 140 psi. Pump 1
will lag and begin pumpping once the tank pressure is below 110 psi.
SHUTDOWN:
1. To stop the air compressor, remove power to the unit
2. Drain air from the air tanks by releasing air with an attached air tool or by pulling on the Safety Relief
Valve.
3. Once the Air Tank Pressure Gauge registers under 10 psi, open the Air Tank Drain Valve under the air tank
to drain any moisture.
4. Allow the air compressor to cool down, then wipe clean.
OPERATING INSTRUCTIONS