Stationary Electric Air Compressor Manual
17
Read the instruction manual before performing maintenance. The following procedures must be performed
when stopping the air compressor for maintenance or service.
1. Turn off air compressor.
2. Open all drains after the tank gauge registers under 10 PSI.
3. Wait for the air compressor to cool before starting service.
WARNING RISK OF BODILY INJURY!
NEVER ASSUME THE AIR COMPRESSOR IS SAFE TO WORK ON JUST BECAUSE IT IS NOT
OPERATING. IT COULD RESTART AT ANY TIME!
MAINTENANCE INSTRUCTIONS
*THE PUMP OIL MUST BE CHANGED AFTER THE FIRST 100 HOURS OF OPERATION AND EVERY
1000 HOURS OR 3 MONTHS, WHICHEVER COMES FIRST.
EVERY TWO YEARS, AN AUTHORIZED SERVICE TECHNICIAN SHOULD CHECK THE CHECK
VALVE, INTAKE VALVES AND DELIVERY VALVES.
AC Ele. Maintenance Chart
MAINTENANCE CHART
PROCEDURE
DAILY
WEEKLY
MONTHLY
1000 HOURS
Check pump oil level
X
Oil leak inspection
X
Drain condensation in air tank (s)
X
Inspect guards/covers
X
Check for unusual noise/vibration
X
Check for air leaks
X
Clean exterior of compressor
X
Inspect air fi lter
X
Inspect belt
X
Check safety relief valve
X
Change pump oil *
X
Replace air fi lter
X