troublesHooting
SYMPTOM
PROBABLE CAUSE
REMEDY
Pump motor will not start, or stops
GFCI tripped.
Turn unit "OFF". Test GFCI by
pressing reset button.
Tripped circuit breaker or fuse
Disconnect all other plugs on the
blown in circuit fuse box.
circuit being used and reset circuit
breaker OR check and replace fuse.
Loose or disconnected plug.
Reconnect plug.
Tripped circuit breaker in unit.
Allow to cool and restart unit.
Unit is frozen.
Allow to thaw. If any part of the unit
becomes frozen; excessive
pressure may build up in the unit
which could cause the unit to burst
resulting in possible serious injury to
the operator or bystanders.
Circuit breaker trips or fuse blows
Circuit overload.
Check that the circuit is rated
in the fuse box.
correctly. Disconnect all plugs on
the circuit. When connecting to a
circuit protected by fuses, use
time delay fuses only.
Extension cord is too long or wire
Use correct electrical requirements.
is too small.
GFCI trips.
Incorrect voltage.
Ensure electrical supply matches
that shown on the I.D. plate.
Electrical short to ground.
Contact Customer Service.
Motor runs but there is no discharge
Inadequate water supply.
Ensure hose is 3/4" diameter and
at nozzle when trigger mechanism is
incoming water supply is turned on.
squeezed.
Kink in water inlet hose.
Remove kink.