Operator’s Manual
3
Specifications
ReCORd SeRIAl numbeR
Write you model number, machine serial number and date
of purchase in the spaces provided below. Your dealer
needs this information when ordering parts.
Model No. ______________________________________________
Machine Serial No. _______________________________________
Date of Purchase ________________________________________
(To be filled in by purchaser)
NOTE:
Unit ratings are established based on operation at standard conditions of 60° F and at sea level. The
performance of the generator must be de-rated for temperature and altitude by 1% for every 10° F above 60° F
and 3.5% for every 1000 feet above sea level. Due to the operational characteristics of the thermal type circuit
breaker, the power available from the generator will decrease slightly with a corresponding increase in ambient
temperature.
Due to continuing product improvements, specifications are subject to change without notice.
SPeCIfICATIOnS
ITem
SPeCIfICATIOn
Gen-2500-0mS0 Gen-3000-0mH0 Gen-3000-1mH0
Gen-4000-0mS0
Gen-4000-0mH0 Gen-5000-0mS0
Engine
Subaru
Honda
Honda
Subaru
Honda
Subaru
Watts (AC) Rated
2500 watts
3000 watts
3000 watts
4000 watts
4000 watts
5000 watts
Watts (AC) Max.
2200 watts
2450 watts
2450 watts
3500 watts
3500 watts
4400 watts
Rated voltage (AC) 20v
20v
20v
20/240v
20/240v
20/240v
Max. Amperage
20.8
25.0
25.0
33.3/6.7
33.3/6.7
4.7/20.8
Cont. Amperage
8.3
20.4
20.4
29.2/4.6
29.2/4.6
36.7/8.3
Frequency
60
60
60
60
60
60
Fuel Tank Capacity .66 gal.
.66 gal.
2.6 gal.
5.68 gal.
5.68 gal.
5.68 gal.
Run Time Hours /
Tank of Fuel*
2.0 hrs.
2.7 hrs.
7.0 hrs.
9.3 hrs.
9.3 hrs.
6.8 hrs.
* Rated at Full Load
Summary of Contents for GEN-2500-0MS0
Page 4: ... Operator s Manual Contents ...
Page 38: ...38 Guide d utilisation Table de matières ...
Page 72: ...72 Manual del Operador Materias ...
Page 102: ...102 Manual del Operador Nota ...