Long Life Vertical LV-Series Operator’s Manual
19
STORAGE & MAINTENANCE
WINTERIZING:
1.
For storage and transportation purposes in subfreezing ambient
temperatures, it will be necessary to winterize this unit. This unit must be
protected to the lowest incurred temperature for the following reasons:
a. If any part of the pumping system becomes frozen; excessive
pressure may build up in the unit which could cause the unit to burst
resulting in possible serious injury to the operator or bystanders.
b. The pumping system in this unit may be permanently damaged if
frozen. FREEZE DAMAGE IS NOT COVERED BY WARRANTY.
If you must store your unit in an area where the temperature may fall below
32°F, you can protect your unit by following the procedure outlined below.
1.
Gather the following items:
a. Two 5 gallon containers.
b. One gallon of antifreeze. (Mi-T-M
®
recommends an environmentally
safe antifreeze.)
c. Water supply.
d. Three foot hose, 1/2-3/4 I.D. with a 3/4 inch male garden hose fitting.
2.
Procedure:
a. To start winterizing, unit must be run and primed according to the
"Start-up Procedures" listed on page 16.
b. After running and priming, shut off the unit and water supply.
c. Relieve system pressure by pointing the trigger gun in a safe direction
and squeezing the trigger until water flow ceases to exit the nozzle.
d. Lock the trigger gun in an OFF position and remove the nozzle.
e. Remove the water supply hose from the unit and attach the 3 foot hose
securely to the inlet connection.
f.
Shut off the detergent injector if applicable.
g. Fill one 5 gallon bucket with water.
h. Holding the 3 foot hose in an upright position, completely fill the hose
with water. Then plug the hose outlet with your thumb or finger. Place
the plugged end into the 5 gallon bucket of water.
i.
Start the unit. Trigger the gun several times until all the air is worked
out of the system (unit is primed). It may be necessary to adjust the
engine RPM down to an idle to aid in priming.
NOTE:
Proper winterizing is based on the recommended manufacturer's
instructions listed on the "Protection Chart" shown on the back label of
most antifreeze containers.
j.
With the trigger gun held open, siphon enough water out of the 5 gallon
bucket until there is just enough water left to mix with the antifreeze.
k. Point the wand into the empty container.
l.
Trigger the gun until the antifreeze begins to exit the wand. Release
the trigger for 3 seconds, then trigger the gun for 3 seconds. Continue
cycling the gun several times until all the antifreeze mixture is siphoned
from the container.
m. Detach the 3 foot hose from the unit and drain any excess antifreeze
back into the 5 gallon container.
n. Disconnect the hose/gun/wand assembly from the unit and drain any
excess antifreeze back into the 5 gallon container.
o. Store the hose, gun and wand with the unit in a safe area.
p. Store antifreeze solution for next use or dispose of according to state
EPA laws.
3.
Optional Procedure:
a. Shut the unit down and turn the water supply off.
b. Relieve system pressure by pointing the trigger gun in a safe direction
and squeezing the trigger until water flow ceases to exit at the nozzle.
c. Disconnect and drain the hose, gun and wand.
d. Start the unit and allow it to run until all the water exits the unit. Once
the water has stopped flowing from the unit, turn off.
NOTE: When using this procedure, caution should be used as ice chips can
form from drops of water which could cause the unit to burst if starting
before completely thawed.
WARNING
RISK OF UNIT BURSTING!
DO NOT STORE/OPERATE UNIT
IN A FREEZING ENVIRONMENT!
PIC-THER.TIF/D1