miAlert 202
1
- www.miAlert.com
3
4 Device LED Indicators
LED Pattern
Red
Blue
Status
1
Normal standby
working state
2
OFF
Send Ack to Pendant/
Device for miPositon
or Heartbeat
3
Repeater Receive
Pendant/Device
Alarm or Heatbeat
OFF
4
OFF
Blinks
500ms
and off every
1sec
Alarm received from
Pendant/Device but
no Ack from
Gateway
5 Specifications
Dimensions: 112mm x 112mm x 22mm.
Weight: 200g with battery inserted.
Operating temperature: 32 to 140°F (0 to 60°C).
Battery type for Back-up: Custom AA 3.6VDC.
Power requirement: 12-24VDC, 200mA.
Storage requirement: Ambient conditions of 69 to 73°F (20.5 to 22.8°C).
UL certification for UL 2560
FCC RF Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. End users must follow the specific operating
instructions for satisfying RF exposure compliance. This transmitter must
not be co-located or operating in conjunction with any other antenna or
transmitter except in accordance with FCC multi-transmitter product
procedures.
FCC Part 15 and Industry Canada Compliance
This device complies with part 15 of the FCC Rules and Industry Canada
license-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause
undesired operation of the device. Changes or modifications not expressly
approved by the party responsible for compliance could void the user's
authority to operate the equipment.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables
aux appareils radio exempts de licence. L'exploitation est autorisée aux
deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage,
et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
Note:
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate the
equipment.
5.a Medical Device Interference
Under FDA and FCC guidelines, the responsibility for verifying continuous
and safe operation of medical devices such as pacemakers and implanted
defibrillators in the presence of electromagnetic interference (EMI) rests
with the manufacturer of the medical device. As such, miAlert does not
have the authority or specific device knowledge to conduct or interpret
formal tests on their behalf.
miAlert transmitter devices comply with Part 15 of the FCC Rules and
Industry Canada license-exempt RSS standards.
If you have any concerns about the use of miAlert transmitter devices in
the presence of medical devices used by a particular resident or patient, we
recommend that you consult with their physician. Another potential source
for answers is the medical device manufacturer, who can provide more
information as to their compliance with federal guidelines and how they
have addressed EMI risk.
5.b Radiation Exposure Limits
This equipment complies with ISED RSS-102 radiation exposure limits set
forth for an uncontrolled environment. End users must follow the specific
operating instructions for satisfying RF exposure compliance. This
transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Cet équipement est conforme avec ISED RSS-102 des limites d'exposition
aux rayonnements définies pour un environnement non contrôlé. Les
utilisateurs finaux doivent suivre le fonctionnement spécifiqueinstructions
pour satisfaire la conformité à l'exposition RF. Cet émetteur doitne pas être
colocalisé ou fonctionner conjointement avec une autre antenne ou
émetteur.
Note:
Users that have achieved certification and will install UL 2560
certified systems are responsible for labeling all fundamental devices with
the UL 2560 system certification mark.
Use c
ompatible
Repeater and
appropriate Gateway
for UL 2560 installations
.
Note:
miAlert supports recycling and reuse whenever possible. Please
recycle these parts using a certified electronics recycler.
Note:
For UL 2560 installations, miAlert repeaters must have 20 minute
check-in times. miAlert transmitters must have a minimum of 60 minute
check-in times.
Note:
In a UL 2560 installation
the miAlert
P
endants
must
be used
to
complete emergency call systems for assisted living and independent
living facilities.
For UL 2560 certified system installations, the following miAlert devices
are approved for installation within maximum system configuration limits
defined in section 1.
b
of this document:
Battery Handling
If you are installing the custom 3.6VDC batteries, keep the batteries
from coming into contact with each other to prevent discharge.
Repeater Shipping
Both lithium-ion and lithium-metal battery types are subject to
transportation regulations such as International Air Transport Association
(IATA), International Maritime Dangerous Goods (IMDG), US Department
of Transportation (DOT) and UN Recommendation on the Transport of
Dangerous Goods.
To prevent accidental alarm activation due to air pressure changes, miAlert
recommends that you avoid shipping the devices by air with the custom
3.6VDC lithium battery installed in the device.
When disposing of this electronic device or depleted custom 3.6VDC
lithium battery, please do so in accordance with federal, state and local
regulations.
OFF
O
N
LED on for
short burst
50ms
O
N