background image

Easidew Portable HP User’s Manual

18

 

 

 

97120 Issue 2.2, March 2016

APPENDIX B

Appendix B 

EU Declaration of Conformity

Summary of Contents for Easidew Portable HP

Page 1: ...Easidew Portable High Pressure Version User s Manual 97120 Issue 2 2 March 2016...

Page 2: ...s information when contacting Michell Instruments for service purposes Analyzer Code Serial Number Invoice Date Location of Instrument Tag No Analyzer Code Serial Number Invoice Date Location of Instr...

Page 3: ...may not be copied or otherwise reproduced communicated in any way to third parties nor stored in any Data Processing System without the express written authorization of Michell Instruments Ltd Easide...

Page 4: ...nts Safety v Electrical Safety v Pressure Safety v Toxic Materials v Repair and Maintenance v Calibration v Safety Conformity v Abbreviations vi Warnings vi Appendices Appendix A Technical Specificati...

Page 5: ...ot allow the battery to fully discharge Pressure Safety DO NOT permit pressures greater than the safe working pressure to be applied to the instrument The specified safe working pressure is 300 barg 4...

Page 6: ...ram lb pound mA milliampere m meter mm millimeter MPa megapascal Nl min normal liters per minute psig pound s per square inch gauge scfh standard cubic feet per hour m micrometer ohm V Volts Warnings...

Page 7: ...f measurement time from a full charge The instrument is delivered complete with a universal battery charger stored in the lid It takes 16 hours to fully charge the battery pack during which time the i...

Page 8: ...letely sealed If the instrument is taken through altitude changes a pressure differential will occur within the case If this occurs Before opening the lid open the black pressure relief valve by one t...

Page 9: ...d 4 Insert the tube adapter until it rests firmly on the shoulder of the Swagelok tube fitting body Finger tighten the nut 5 Mark the nut at the 6 o clock position While holding the fitting body stead...

Page 10: ...as supply line to the instrument Gas In port 5 Connect the sample gas vent line to the instrument Gas Out port 6 Switch the instrument on The display will begin to change as the sensor responds to the...

Page 11: ...t Dew Point T100 Response Time mins C F 30 22 15 40 40 30 50 58 60 60 76 180 The Easidew sensor fitted to the Easidew Portable is designed and calibrated to measure dew points as low as 100 C 148 F Ho...

Page 12: ...the instrument it can be accessed by removing two screws 5 The battery pack can be recharged using the supplied charger via the battery charging socket and should be recharged whenever the battery le...

Page 13: ...ter vapor as the water molecule is extremely small compared to the structure of solids even when compared to the crystalline structure of metals The graph to the right shows the dew point inside tubin...

Page 14: ...point should always be as close to the critical measurement point as possible in order to obtain a truly representative measurement The length of the sample line to the sensor or instrument should be...

Page 15: ...id droplets and can even stop flow to the analyzer completely when a large slug of liquid is encountered Condensation and Leaks Dewpoint T Dewpoint T Maintaining the temperature of the sample system t...

Page 16: ...this problem Slow the response of the sensor to changes in moisture content An excessively high flow rate can Introduce back pressure causing slower response times and unpredictable effects on equipme...

Page 17: ...nt To remove the sensor or battery pack 1 Ensure instrument is switched off and that the battery charger current output and any sampling components are also disconnected 2 Remove and retain the 10 cro...

Page 18: ...below Completely unscrew the cable gland on the GDSN connector to release the cable tension Remove the locking screw from the back of the connector retaining the metal O ring Remove the connector bloc...

Page 19: ...ure 3 2 Wire Connection View Showing Rear of Connector Terminal Block To verify the display electronics are within calibration a 4 20mA current source can be connected in place of the sensor At 4 mA t...

Page 20: ...4 20mA source Exchange sensor Display shows ErrH Sensor reading over range Sensor current signal 20mA Sensor tile short circuit Sensor may have been exposed to saturation conditions or liquid contami...

Page 21: ...Easidew Portable HP User s Manual Michell Instruments 15 APPENDIX A Appendix A Technical Specifications...

Page 22: ...age Temperature 40 to 75 C 40 to 167 F Operating Pressure Up to 30 MPa 300 barg 4350 psig Mechanical Specifications Display Flush mounted 3 5 digit red LED Case Yellow propylene with charger and outpu...

Page 23: ...Easidew Portable HP User s Manual Michell Instruments 17 APPENDIX B Appendix B EC Declaration of Conformity...

Page 24: ...Easidew Portable HP User s Manual 18 97120 Issue 2 2 March 2016 APPENDIX B Appendix B EU Declaration of Conformity...

Page 25: ...Easidew Portable HP User s Manual Michell Instruments 19 APPENDIX C Appendix C Quality Recycling Warranty Information...

Page 26: ...Directive and the Restriction of Hazardous Substances RoHS Directive place rules upon European manufacturers of electrical and electronic equipment The directives aim is to reduce the impact that ele...

Page 27: ...full description of the fault and the customer contact information 3 Upon receipt Michell Instruments will evaluate the product to determine the cause of the malfunction Then one of the following cour...

Page 28: ...Easidew Portable HP User s Manual 22 97120 Issue 2 2 March 2016 APPENDIX D Appendix D Decontamination Declaration...

Page 29: ...ls YES NO Radioactive substances YES NO Other hazards YES NO Please provide details of any hazardous materials used with this equipment as indicated above use continuation sheet if necessary Your meth...

Page 30: ...Easidew Portable HP User s Manual 24 97120 Issue 2 2 March 2016 NOTES...

Page 31: ...Easidew Portable HP User s Manual Michell Instruments 25 NOTES...

Page 32: ...http www michell com...

Reviews: