EDM MD-S Series
Installation Manual
Page 12 of 23
5.2 Control Box Assembly EDM MD
No.
1.
Power Input Plug in 200~240VAC
2. RUN/PRG switch
Slide switch to change from RUN mode to PROGRAM mode
3. TEST / UP & SET Buttons
RUN Mode Only
TEST Button
–
Used to check the basic function of the operator when servicing or in-
stallation. Activation signal for Test open cycle.
UP & SET Button
–
Used when in PROGRAM mode only. (To entre Programming
mode: Slide switch from RUN to PROG.)
PROGRAM Mode only
<How to RESET>
UP SET
ON ON : Hold both buttons to RESET. Set to “RUN”, then teaching starts.
UP & SET Button
–
Push and Hold together. After releasing buttons, LED shows open
counter. “OP ** ** ** **” (8 Digits).
<How to change setting>
UP SET
ON OFF : Change LED 1 value
OFF ON : LED 2 flash
ON OFF : Change LED 2 value
OFF ON : Value is fixed (LED 1/2 lights are on)
(Repeat this to change setting)