4. LED Display
LED Display is a visual display for the installer in order to correctly set up and operate
MICOM EDM MD Operator.
LED DISPLAY:
LED1 : Function / Application
LED2 : Parameter Value
Green LED : Power indicator
Red LED : Sensor indicator (SS or SB)
‘RUN’ Mode
When in ‘RUN’ mode, the operator will run as
normal. LED display will show:
a.
Number of open cycles. (Memory is cleared by main-power off).
b.
Error indication
Error Code:
E0 : Door travel distance during teaching cycle is too short (less than 150mm).
E1 : Open error (Obstruction during the opening cycle)
E2 : Closer error (Obstruction during the closing cycle)
E4 : Loose belt (Longer stroke than stored data)
E6 : E-lock error (no un-lock signal input)
‘PROGRAM’ Mode
When in PROGRAM mode, changes to operational parameter values can be made.
(To entre Programming mode: Slide switch from RUN to PROG.)
See setting table. Sec 6.
5.SW4
Note : After changing setting of SW4, turn the main power OFF/ON to save the ad-
justment.
SW1 : Opening direction
SW2 : RS function (Ratchet or Flip Flop)
SW3 : Close pressing
–
Set ON if the motor generates vibration at the closed position.
Closing Press function will be cut off 2-3 sec after fully closed. Otherwise Close Press is
always on.
Set OFF
–
Always closing press at closed position.
SW4 : E-lock (set OFF when E-lock is connected (YES)
6.Motor Plug
Connection of Motor to Control by Plug in
7. Sensor Harness
Connection of Sensor Harness to Control by Plug in
8. E-Lock
Relay Output (NO or NC) (DC24V 300mA)
9. DC 24V
Output for E-Lock (Can also be used for Sensors/ Accessories) (DC 24V 300mA)