EDM MD-S Series
Installation Manual
Page 14 of 23
6. Setting
6.1 Basic Setting Code (Set the slide switch to PROGRAM)
Code
Function
Volume
Factory
setting
Remarks
LED1
LED2
0
Hold Open Time
1
~
F
1
1-9sec, A:10sec, B:20sec, C:30sec, D:40sec, E:50sec F:60sec.
1
Open High
Speed
0
~
A
7
Setting of open high speed
2
Open Low Speed
0
~
A
4
Setting of open low speed
3
Open Break
Force
0
~
A
5
Setting of open break force
4
Open Force
0
~
A
5
Setting of open motor torque
5
Close High
Speed
0
~
A
5
Setting of close high speed
6
Close Low Speed
0
~
A
4
Setting of close low speed
7
Close Break
Force
0
~
A
5
Setting of close break force
8
Close Force
0
~
A
3
Setting of close motor torque
9
Partial Open
Width
0
~
3
1
Partial open is available by HO signal.
0:35%, 1:50%, 2:65%, 3:80%
A
Open Delay (*)
0~3
1
0 : No delay time after un-lock signal is confirmed.
1/2/3 : Below delay time from SS is activated to door starts to
open.
< 1:0.1sec, 2:0.5sec, 3:1.0 sec.>
When set 1/2/3/, door opens regardless of whether unlock sig-
nal.
If E-Lock can output unlock signal, it must be set "0".
B
Mode Switching
0~2
0
0 : HO (Half Open)
1 : AS (Side Screen Safety)
2 : ES (Emergency Stop)
(*) :
This function is available when SW4-4 is set OFF
When SW-4 is set ON, door starts to open upon SS without delay.