background image

EDM MD-S Series 
Installation Manual  

 

 

Page 9 of 23 

 

 
3.3 EDM-MD Front View 

 

 
 

Summary of Contents for EDM MD-S Series

Page 1: ...eries Installation Manual Page 1 of 23 MICOM AUTODOOR Automatic Sliding Door Operator Model EDM MD S Original Instructions INSTALLATION MANUAL OSAKA JAPAN www micomautodoor com REVISED DATE MARCH 2018...

Page 2: ...able for the loca tion Before installing the drive check the driven part is in good mechanical condition correctly bal anced and opens and closes properly This drive is intended to be installed at a h...

Page 3: ...a person can be avoided by laying any heavy object horizontally onto the floor to one side of the working area Risk of slipping tripping or falling can be avoided by placing any removed objects to on...

Page 4: ...peration 3 6 Power On 4 Teaching Learning 4 1 Teaching Learning Operation 5 Set Up Operation 5 1 Motor Gear Box 5 2 Control Box 6 Setting Table 6 1 Basic Setting Code 6 2 Hold Open Timer 6 3 Partial O...

Page 5: ...tallation through an easily accessible visual LED display found on MD Control box face Easily accessible connections are located either as an independent terminal on the rail or by adding MICOM Sensor...

Page 6: ...kets x4 and stopper x 2 Rail Cover Materials Only Standard Length Single Leaf 2100mm Double leaf 4200mm SHORT KIT Retro Fit YII ZII GII Rail UNDER DEVELOPMENT consisting of Control Box Connection Har...

Page 7: ...ket Assembly 2 Hanger Roller Bracket with Belt Bracket Link Assembly Single Leaf 3 Tooth Belt 4 Hanger Roller Bracket with Double Roller Standard 5 EDM MD Control Box 6 EDM MD Motor Gear Box Assembly...

Page 8: ...rian access at all times dur ing works being carried out Positioning and Installing base rail Refer to below EDM MD Drawing to find correct measurement of base rail position Ensure hanger roller brack...

Page 9: ...EDM MD S Series Installation Manual Page 9 of 23 3 3 EDM MD Front View...

Page 10: ...re correctly installed Refer to wiring diagrams Sec 8 The power switch is located to the right of motor fixed to the underside of the base rail 4 Teaching Learning Operation CAUTION Ensure that the do...

Page 11: ...re learn it s stoke In case of a malfunction or in the event that the stored data is affected by electric noise during its operation the controller can be recovered by another RESET We recommend taki...

Page 12: ...on Activation signal for Test open cycle UP SET Button Used when in PROGRAM mode only To entre Programming mode Slide switch from RUN to PROG PROGRAM Mode only How to RESET UP SET ON ON Hold both butt...

Page 13: ...ata E6 E lock error no un lock signal input PROGRAM Mode When in PROGRAM mode changes to operational parameter values can be made To entre Programming mode Slide switch from RUN to PROG See setting ta...

Page 14: ...e Low Speed 0 A 4 Setting of close low speed 7 Close Break Force 0 A 5 Setting of close break force 8 Close Force 0 A 3 Setting of close motor torque 9 Partial Open Width 0 3 1 Partial open is availab...

Page 15: ...ced in the threshold and not detected by safety devices the following obstruction detec tion function will ensure safe operation as follows 7 1 During closing travel On contact with object doors will...

Page 16: ...ustable 160 500mm s 11 steps adjustable Close Door Speed Adjustable 160 400mm s 11 steps adjustable Power Consumption 200 240V AC 0 7A Power Output 24V DC 300mA Motor DC 24V 55W Brushless Braking Adju...

Page 17: ...nction Selectors are easy to in stall and operate Supplied in a fire retardant black plastic mount box with attractive cover design in white our func tion selectors can be fitted to walls or aluminium...

Page 18: ...Series Installation Manual Page 18 of 23 10 3 MICOM Function Selector Switch Wiring Drawing 4 Position with Rotary Knob Available in 2 configurations 10 3 1 Rotary Function Selector Switch 4 Position...

Page 19: ...EDM MD S Series Installation Manual Page 19 of 23 10 3 2 Rotary Function Selector Switch 4 Positions with Push Button Emergency Exit Option...

Page 20: ...EDM MD S Series Installation Manual Page 20 of 23 11 Electromagnetic Lock Wiring...

Page 21: ...F Steps 1 1 Open High Speed 500mm s MAX 0 A Steps 7 2 Open Low Speed 0 A Steps 4 3 Open Brake Force 0 F Steps 5 4 Open Force 0 A Steps 5 5 Close High Speed 400mm s MAX 0 A Steps 5 6 Close Low Speed 0...

Page 22: ...appropriate national authorities relevant information on the partly completed machinery identified above The method of transmission shall be by mail This partly completed machinery must not be put in...

Page 23: ...Flr Dobson House Regent Centre Gosforth Newcastle Upon Tyne NE3 3PF U K Tel 44 191 2336323 E Mail info micomautodoor com Copyright 2018 MICOM Autodoor The contents of the document are the sole propert...

Reviews: