Parameter
Address
Default
Min
Max
Unit
Logic Diagram
[spacer]
DTOC2: tI>> PSx
076 078
077 078
078 078
079 078
0.50
0.00
100.00
s
[spacer]
Setting for operate delay I>>.
[spacer]
DTOC1: tI>>> PSx
076 059
077 059
078 059
079 059
0.50
0.00
100.00
s
[spacer]
DTOC2: tI>>> PSx
076 169
077 169
078 169
079 169
0.50
0.00
100.00
s
[spacer]
Setting for the operate delay of the I>>> stage.
[spacer]
DTOC1: Ineg> PSx
076 197
077 197
078 197
079 197
0.25
0.10
8.00
Inom
[spacer]
DTOC2: Ineg> PSx
076 207
077 207
078 207
079 207
0.25
0.10
8.00
Inom
[spacer]
Setting for the operate value of the Ineg> stage.
[spacer]
DTOC1: Ineg>> PSx
076 198
077 198
078 198
079 198
Blocked
0.10
8.00
Inom
[spacer]
DTOC2: Ineg>> PSx
076 208
077 208
078 208
079 208
Blocked
0.10
8.00
Inom
[spacer]
Setting for the operate value of the Ineg>> stage.
[spacer]
DTOC1: Ineg>>> PSx
076 199
077 199
078 199
079 199
Blocked
0.10
8.00
Inom
[spacer]
DTOC2: Ineg>>> PSx
076 209
077 209
078 209
079 209
Blocked
0.10
8.00
Inom
[spacer]
Setting for the operate value of the Ineg>>> stage.
[spacer]
DTOC1: Ineg> dynamic PSx
076 200
077 200
078 200
079 200
1.00
0.10
8.00
Inom
[spacer]
DTOC2: Ineg> dynamic PSx
076 210
077 210
078 210
079 210
1.00
0.10
8.00
Inom
[spacer]
Setting for operate value Ineg> dynamic. (Ineg = negative-sequence current)
This operate value is effective only while the timer stage MAIN: Hold time
dyn.param. is elapsing.
[spacer]
DTOC1: Ineg>> dynamic PSx
076 201
077 201
078 201
079 201
1.00
0.10
8.00
Inom
P631
7 Settings
7-110
P631/EN M/R-11-C // P631-310-650
Summary of Contents for P631
Page 2: ......
Page 4: ......
Page 7: ...Changes after going to press...
Page 8: ......
Page 16: ...P631 Table of Contents 8 P631 EN M R 11 C P631 310 650...
Page 56: ...P631 2 Technical Data 2 28 P631 EN M R 11 C P631 310 650...
Page 236: ...P631 3 Operation 3 180 P631 EN M R 11 C P631 310 650...
Page 246: ...P631 4 Design 4 10 P631 EN M R 11 C P631 310 650...
Page 266: ...P631 5 Installation and Connection 5 20 P631 EN M R 11 C P631 310 650...
Page 276: ...6 8 Configurable Function Keys P631 6 Local Control HMI 6 10 P631 EN M R 11 C P631 310 650...
Page 548: ...P631 10 Commissioning 10 10 P631 EN M R 11 C P631 310 650...
Page 568: ...P631 12 Maintenance 12 8 P631 EN M R 11 C P631 310 650...
Page 570: ...P631 13 Storage 13 2 P631 EN M R 11 C P631 310 650...
Page 572: ...P631 14 Accessories and Spare Parts 14 2 P631 EN M R 11 C P631 310 650...
Page 576: ...P631 15 Order Information 15 4 P631 EN M R 11 C P631 310 650...
Page 582: ...P631 A2 Internal Signals A2 4 P631 EN M R 11 C P631 310 650...
Page 608: ...P631 A4 Telecontrol Interfaces A4 18 P631 EN M R 11 C P631 310 650...
Page 637: ......