2.9
Deviations
2.9.1
Deviations of the Operate Values
2.9.1.1
Definitions
Reference Conditions
●
Sinusoidal signals at nominal frequency fnom, total harmonic distortion
≤
2
%, ambient temperature 20°C (68°F), and nominal auxiliary voltage V
A,nom
.
Deviation
●
Deviation relative to the setting under reference conditions.
2.9.1.2
Differential Protection
Measuring system
●
at I
diff
< 0.2·I
ref
: ± 10%
●
at I
diff
>= 0.2·I
ref
: ± 5%
Inrush Stabilization (Harmonic restraint)
●
Deviation: ± 10%
2.9.1.3
Restricted Earth-Fault Protection
●
Measuring system at I
d
= 0.2·I
ref
: ± 5%
2.9.1.4
Overcurrent-Time Protection
Operate values
●
Deviation: ± 5%
2.9.1.5
Thermal Overload Protection
Operate value
Θ
●
Deviation: ± 5%
2.9.1.6
Frequency Protection
Operate values f<>
●
± 30 mHz (
f
nom
= 50 Hz)
●
± 40 mHz (
f
nom
= 60 Hz)
P631
2 Technical Data
2-18
P631/EN M/R-11-C // P631-310-650
Summary of Contents for P631
Page 2: ......
Page 4: ......
Page 7: ...Changes after going to press...
Page 8: ......
Page 16: ...P631 Table of Contents 8 P631 EN M R 11 C P631 310 650...
Page 56: ...P631 2 Technical Data 2 28 P631 EN M R 11 C P631 310 650...
Page 236: ...P631 3 Operation 3 180 P631 EN M R 11 C P631 310 650...
Page 246: ...P631 4 Design 4 10 P631 EN M R 11 C P631 310 650...
Page 266: ...P631 5 Installation and Connection 5 20 P631 EN M R 11 C P631 310 650...
Page 276: ...6 8 Configurable Function Keys P631 6 Local Control HMI 6 10 P631 EN M R 11 C P631 310 650...
Page 548: ...P631 10 Commissioning 10 10 P631 EN M R 11 C P631 310 650...
Page 568: ...P631 12 Maintenance 12 8 P631 EN M R 11 C P631 310 650...
Page 570: ...P631 13 Storage 13 2 P631 EN M R 11 C P631 310 650...
Page 572: ...P631 14 Accessories and Spare Parts 14 2 P631 EN M R 11 C P631 310 650...
Page 576: ...P631 15 Order Information 15 4 P631 EN M R 11 C P631 310 650...
Page 582: ...P631 A2 Internal Signals A2 4 P631 EN M R 11 C P631 310 650...
Page 608: ...P631 A4 Telecontrol Interfaces A4 18 P631 EN M R 11 C P631 310 650...
Page 637: ......