6. After assigning a value to F, wait for the motor to stop turning (normally no more than a
minute). When the motor stops, close the door and fix the arm to the motor pivot.
7. T
hen press “-TEST” once more to save the changes and to check that the letter “F”
disappears from the screen.
8. Disconnect the operator from the electricity supply
9. Open the door manually and check that it closes by itself.
10. Adjust the end of the run.
6.5 Adjusting Opening Limit
Steps to follow:
1. Loosen the screw for the limit lever so that it can move and turn freely.
2. Open the door to the desired opening point. If the operator is spring closing, it is necessary to apply
either a door stopper or something similar so that the door stays open, until finished adjusting the
limit.
3. Turn the lever until the final limit is obtained.
Loosen with Allen
key 3