MICOM SWING SW & SWSP
Installation Manual
Page
22
4
. Tighten the lever screw so that it is fixed firmly to the motor pivot.
7. OPERATION OF MICOM SWING SW & SWSP UNIT
7.1 Start Up and Self Learning
IMPORTANT NOTICE: When the MICOM SWING SW & SWSP system starts up for the first time, the
self-adjustment process will start for the system. This process will carry out an opening and closing
cycle to find the actual length of the door stroke.
It is very important to allow the door to carry out these cycles freely, i.e. with no obstacles. It is
therefore recommended that no-one goes near the door. If the panel has any obstruction during the
learning cycle, the whole process should be re-started via the RESET on the control unit (see section
12.2.5 - for more information).
During the Self-learning process, the automatic door will automatically carry out the following actions:
1. Prior to starting, ensure that the operator selector has been connected, as well as the electricity
supply, transformer, motor and the control unit.
2.Plug in connector to the supply situated to the right of the Control Unit and place the operator
selector on any function, except that of closing or manual.
3.The door opens slowly until it reaches its opening position.
4.The door closes slowly until it reaches its closing position.
5.From here on the door will work normally, although the first movements will often brake early. As the
operator continues with the closing and opening cycles, the door will gradually find the most efficient
braking point.
This process is only carried out on the first occasion when the automatic door is activated and
every time the RESET is used. (s
ee section“12.2.5.-”).
If for any reason you are unable to carry out the Self-learning process correctly, you must go
through the process again through “RESET” on the Control Unit.
Tighten with Allen
key 3