MICOM SWING SW & SWSP
Installation Manual
Page
23
Every time that important changes take place on the automatic door, such as: change of
position of the stoppers, change to the size of the panels or change to the weight of the
panels, in these cases you always have to do a “RESET” in order for the Control Unit to adapt
to the changes.
After carrying out a
“RESET” on the Control Unit, as well as re-starting the Self-learning, the
parameters will be cancelled off and will return to the factory settings. There are certain
parameters
that will not cancel off after a “RESET”, such as: the number of cycles and the
function time.
7.2
Normal Function
In order to ensure that the System is working correctly, check the
“POWER ON”, located on the
Control Unit is always switched ON.
When the Control Unit receives an impulse to open (for example, a movement sensor, an emergency
command or switch/
sensor) the “INPUT ON” on the display screen will activate. The motor will then
start to turn and provide movement to the automatic door panels to open.
When there is no signal to open, the motor will turn in reverse direction until the door is fully closed.
When it receives the signal to stop (by means of pressing the emergency stop button) the door will
brake and will remain still while the signal to stop is in place.
POWER ON
INPUT ON