7.3 Electrical Fault
If the operator is equipped with a battery system (optional) and there is a cut in the electricity supply,
the door will continue to function normally until the battery is dead.
Once the battery is almost empty, the automatic door will cease to function until the general electricity
supply returns or until the “Night Bank” or Night Switch is activated.
I
f the “Night Bank” (switch) comes into action, it will activate the battery system and the motor will
open/close the door.
When the electricity supply fails and if the operator is not equipped with a battery system:
- with the MICOM SWING-SW model will stop working.
- with the MICOM SWING-SWSP model the door will only close.
7.4 Errors
A case could occur where the system has suffered a problem and therefore would cease to function
correctly, e.g. in the event of a power cut or when the automatic door hits a pedestrian.
In these cases, the automatic door will give both a visual and acoustic signal to indicate what error
has taken place (for
more information see section”14. PROBLEM SOLVING. ERROR TABLE”).