MICOM SWING SW & SWSP
Installation Manual
Page
33
9.9 P9 Connector. Internal movement sensor (Internal Sensor)
The P9 connector is used to connect a motion sensor.
The connector consists of 4 poles:
●
Two poles are used to supply the sensor. The output is 24V DC.
●
The other two poles are the input of the sensor signal, which can be: free of voltage (relay
output, no polarity) or by transistor (with polarity).
The signal input is programmed at the factory to act as a Normally Open contact. It can also be
configured as Normally Closed contact (see
section “13.-PROGRAMMING PARAMETRES” -
Parameter Nº19).
9.10
P8 Connector. External movement sensor (External Sensor)
The P8 connector is used to connect a movement sensor.
The connector consists of 4 poles:
●
Two poles are used to supply the sensor. The output is 24V DC.
●
The other two poles are the input of the sensor signal, which can be: free of voltage (relay
output, no polarity) or transistor (with polarity).
The input signal is programmed from the factory to act as a Normally Open contact, although it can be
configured as a Normally Closed contact as well (
see section “13.-PROGRAMMING PARAMETRES”
- Parameter
Nº20”).