MICOM SWING SW & SWSP
Installation Manual
Page
35
In the event of needing more than one security sensor with NC (Normally Closed) contacts there
needs to be a connection in series with the signal sensors, just as can be seen in the following figure:
9.12
P14 Connector: Opening Safety Sensor 2 (Security 2)
The P14 connector is used to connect the security sensor. This sensor protects from possible
collisions of door opening movement.
The connector consists of 4 poles:
●
Two poles are used to feed the sensor. The output feed is 24V DC.
●
The other two poles are the input of the sensor signal, which can be: free of voltage (relay
output, no polarity) or transistor (with polarity).
The signal input comes programmed from the factory to act as Normally Open contact, although it can
be configured as a Normally Clos
ed contact as well (see section “5.3.-PROGRAMMING
PARAMETRES” - Parameter Nº33”).
Its connection is identical to that of the P10 connector except that it is carried out in the P14
connector.