MICOM SWING SW & SWSP
Installation Manual
Page
39
resume the same state as to prior to the power cut.
In order to activate the WITH MEMORY mode, the
‘Automatic’ button must be pressed down for 5
seconds.
Note: This programming mode has been implemented by the factory.
10. DOULE DOOR OPERATION (DUAL)
Installation of Double Swing operation:
●
Two operators are used in double doors - one for each door. Install both operators (for more
information see section 5.-OPERATOR INSTALLATION).
●
Place a bridge P17 in each of the control units (this comes installed from the factory).
●
Connect the TX signal from the P11 connector from operator 1 with the TX signal connector
P11 of operator 2. Connect the RX signal of the P11 connector of operator 1 with the RX
signal of the P11 connector of operator 2.
●
Check the resistance value w
ith a polimetre (Ω) between TX and RX. If everything is correct,
you should obtain a value between 55 and 65
Ω. If this is not the case, check that a bridge
has been done on P17. If you continue to receive an incorrect value, remove the bridge
situated in the B selectors (digital).
●
Go into programming and assign the following values to the Master door:
●
Parameter 37 = 1
●
Go into programming and assign the following values to the Slave door:
●
Parameter 37 = 2
●
It may be required to alter the following parameters relating to the double doors:
●
Parameter 38, Parameter 41, Parameter 42.