MICOM SWING SW & SWSP
Installation Manual
Page
42
12.2.3 Exit Programming Menu & Saving Modifications
In order to exit the programming menu and save all the changes carried out, you must do the
following:
●
Go into the “00”parametre
●
Press “ENTER”
●
Press “+”
12.2.4 Programming Example
We wish to change the option how the emergency stop works and we want this function to act as
normally closed contact. In order to do this we need to follow the following steps:
●
If the door is working, we have to wait until it finishes opening or closing. In order to avoid
possible accidents while we reprogrammed, we recommend putting the function selector at
“door closed” or “door open”.
●
Hold
the “ENTER” button for 5 seconds until the display screen shows the “00” message.
●
Now press 22 times on the “+”, that is until the number 22 appears on the display (if we look
at the table from sectio
n “5.3.- Programming parameters”, we will see that 22 represents the
emergency stop parameter).
●
Press “ENTER”. The display screen will show the “=0” value which indicates that the
emergency stop is configured to work as a normally open contact.
●
Press “+”. The display screen will show the “=1” value which indicates that the emergency
stop is configured to work as a normally closed contact.
●
Press
“ENTER”. The display screen will show the value “22”.
●
At this moment, the emergency stop has been programmed as a normally closed contact.
Now we are need to Exit the programming and save the data:
●
Press “-“ 22 times, i.e. until the value of “00” appears on the display screen.
●
Press “ENTER”.
●
Press “+”.