MICOM SWING SW & SWSP
Installation Manual
Page
44
13. PROGRAM PARAMETERS
Parameter
Description
Adjust
Value
Factory
Setting
00
Exit programming
01
Display screen rotation
From 0 to 2
0
Value 0 = Automatic
Value 1 = Normal
Value 2 = Reserve
02
Automatic Closing Timer
From 1 to 9
2
Value 1 = 1 second
Value 2 = 2 seconds
Value 3 = 3 seconds
Value 4 = 4 seconds
Value 5 = 5 seconds
Value 6 = 10 seconds
Value 7 = 20 seconds
Value 8 = 30 seconds
Value 9 = 60 seconds
03
Opening Speed
From 0 to 9
6
Value 1 = 15º/s
Value 2 = 25º/s
Value 3 = 35º/s
Value 4 = 45º/s
Value 5 = 50º/s
Value 6 = 55º/s
Value 7 = 60º/s
Value 8 = 65º/s
Value 9 = 75º/s
04
Closing Speed
From 0 to 5
2
Value 1 = 15º/s
Value 2 = 25º/s
Value 3 = 35º/s
Value 4 = 45º/s
Value 5 = 50º/s
05
Dynamic Opening Force
From 1 to 9
9
Value 1 = Even Minimum Strength
Value 9 = Even Maximum Strength
06
Dynamic Closing Force
From 1 to 9
9
Value 1 = Even Minimum Strength
Value 9 = Even Maximum Strength