MICOM SWING SW & SWSP
Installation Manual
Page
45
07
Opening Deceleration
From 0 to 9
5
Value 0 =Gradual Deceleration
Value 9 = Rapid Deceleration
08
Closing Deceleration
From 0 to 9
0
Value 0 = Gradual Deceleration
Value 9 = Rapid Deceleration
09
Static Opening Force
From 0 to 4
0
Value 0 = 0 N
Value 1 = 10 N
Value 2 = 20 N
Value 3 = 30 N (recommended in areas of high winds)
Value 4 = 40 N ((recommended in areas of high winds)
10
Static Closing Force
From 0 to 4
1
Value 0 =0 N (recommended when using the Push&Go)
Value 1 = 10 N
Value 2 = 20 N
Value 3 = 30 N (recommended in areas of high winds)
Value 4 = 40 N (recommended in areas of high winds)
11
Push & Go
0 or 5
0
Value 0 = Deactivated
Value 1 = Activated in 2º
Value 2 = Activated in 3º
Value 3 = Activated in 5º
Value 4 = Activated in 9º
Value 5 = Activated in 15º
12
Acoustic Warning
0 or 1
1
Value 0 = Deactivated
Value 1 = Activated
13
Brake Point on Opening
From 0 to 6
2
Value 0 = At 0º of the total opening
Value 1 = At 5º of the total opening
Value 2 = At 10º of the total opening
Value 3 = At 15º of the total opening
Value 4 = At 20º of the total opening
Value 5 = At 25º of the total opening
Value 6 = At 30º of the total opening
14
Brake Point on Closing
From 0 to 6
2
Value 0 = At 0º of closing (this value is only available if there is
no automatic bolt)
Value 1 = At 5ºof closing (this value is only available if there is no
automatic bolt)