MICOM SWING SW & SWSP
Installation Manual
Page
46
Value 2 = At 10º of closing
Value 3 = At 15ºof closing
Value 4 = At 20ºof closing
Value 5 = At 25º of closing
Value 6 = At 30º of closing
15
Electromagnetic Lock
From 0 to 4
1
Value 0 = No Lock Fitted (recommended when using Push&Go)
Value 1 = Automatic Bolt unlocked with 12/24Vdc;
and locked with 0V. *
Value 2 = Automatic Bolt unlocked with 0V;
and locked with 12/24Vdc. *
Value 3 = Automatic Bolt unlocked with 12/24Vdc;
and locked with 0V. **
Value 4 = Automatic Bolt unlocked with 0V;
and locked with 12/24Vdc. **
* It unlocks just prior to the door opening and during the first
0º~20ºof opening.
** It unlocks just prior to the door opening and during the entire
process of opening/closing.
16
Electromagnetic Lock Release Force
From 0 to 4
1
Value 0 = 10N
Value 1 = 15N
Value 2 = 20N
Value 3 = 25N (recommended in areas of high winds)
Value 4 = 30N (recommended in areas of high winds)
17
Acoustic Warning prior to Closing
0 or 1
0
Value 0 =Deactivated warning
Value 1 = Activated warning
18
Safety Sensor in Monitoring Mode (Closing side)
0 or 1
0
Value 0 =Monitoring Mode deactivated
Value 1 =Monitoring Mode activated
19
Internal Activation Sensor / Device Input
From 0 to 2
0
Value 0 = NO (Normally Open).
Value 1 = NC (Normally Closed).
Value 2 = Bi-stable.
20
External Activation Sensor / Device Input
0 or 1
0
Value 0 = NO (Normally Open).
Value 1 = NC (Normally Closed).