MICOM SWING SW & SWSP
Installation Manual
Page
49
Value 2 = The master door will open before the slave door and
they close at the same time
39
Function of the Channel 2 receptor
From 0 to 2
0
Value 0 =Close the door immediately
Value 1 = Activates and deactivates the Push & Go (one beep
confirms the activation; two beeps the deactivation)
Value 2 = Activates and Deactivates the function of door opening
40
Lock Out (Opening Against a Wall or Fixed Structure)
From 0 to 2
0
Value 0 = No Wall or Fixed Structure
Value 1 = Opening Safety sensor (safety 2) is deactivated last 10º
of opening
Value 2 = Opening Safety sensor (safety 2)is deactivated last 20º
of opening
41
Master & Slave Door Offset
From 0 to 4
0
Value 0 = 5º
Value 1 = 10º
Value 2 = 15º
Value 3 = 20º
Value 4 = 25º
42
Master & Slave Door Closing Offset
From 0 to 5
0
Value 0 = No security distance
Value 1 = 5º
Value 2 = 10º
Value3 = 20º
Value 4 = 30º
Value 5 = 40º
43
Internet System (Optional)
From 0 to 2
0
44
Internet System (Optional)
From 0 to 9
0
45
Obstruction Sensitivity
From 0 to 4
0
Value 0 = very low (it takes 4sec. to detect an obstruction)
Value 1 = low (it takes 3sec. to detect an obstruction)
Value 2 = medium (it takes 4sec. to detect an obstruction)
Value 3 = high (it takes 1sec. to detect an obstruction)
Value 4 = very high (it takes 0.5sec. to detect an obstruction)
46
Automatic bolt unlocked on
‘manual function mode’
From 0 to 1
0
Value 0 = Deactivated
Value 1 = Activated
50
Technical Diagnostics
From 0 to 7
Value 1 = Number of cycles completed.
Display will show the number of cycles via digits, scrolling from left
hand digit.