Notes: For more information, please read the “Section 3.1” of the Installation Manual.
In certain installations of automatic doors, some installers may sometimes place
operation selector cables and power supply cables (230Vac) within the same tube.
This must never be done as it may cause, in the short or long term, the
microprocessor to work incorrectly or to break down irreversibly.
It is advised to avoid placing cables within the same tube. Those belonging to the
automatic door must be shielded and properly grounded at both ends.
It is always necessary to try to separate signal cables (photocell, selector, radars,
engine, etc.) from voltage cables (230V or 110V).
IMPORTANT SAFETY NOTICE!!!
When the door starts for the first time, it will automatically perform a series
of opening and closing cycles (normally between 3 to 5 times)
– Known as
teaching or self-learning mode.
Please note these learning cycles are performed at high speed without
safety features enabled.
Keep clear of the entrance and doors. Ensure that no pedestrians pass
through the doors during the initial learning, installation or maintenance.
Keep clear of doors when opening or closing during learning. It is advisable
to identify and restrict the area with warning signs.