MICOM SWING SW & SWSP
Installation Manual
Page
53
sensor
(monitoring
the opening)
- If the problem persists, replace the security sensor with a new
one.
E5
_ _ _ _ _ __
Broken belt
or reducer of
the broken
motor
- Check the good working state of the motor belts. If the belt is
damaged, replace it with a new one.
- Test the motor to turn manually. In the event that it does not turn
easily (a small force applied to the end of the arm should make it
turn), replace the motor with a new one of identical characteristics.
E6
_ _ _ _ _ _ __
Error in the
supervision
of the
closing
security
sensor(moni
toring)
- Check that the security sensor connected has the supervision
option activated (Monitoring).
- Check that the security sensor is correctly connected.
- If the problem persists, replace the security sensor with a new
one.
E7
_ _ _ _ _ _ _
__
Emergency
open in the
case of an
electrical
fault
- If there has been an electrical fault, then it is normal that this
error appears.
- If there has been no electrical fault, check that the supply
connection on the Control Unit has a voltage of between 100V and
230V AC.
- If the problem persists, change the Control Unit with a new one.
E8
_ _ _ _ _ _ _ _
__
Error in the
automatic
bolt
- The automatic door is closed and will not open. Check that the
automatic lock is connected and is working correctly.
- Check that the automatic lock parameter has been programmed
correctly (see section “5.3.-PROGRAMMING PARAMETRES”
parameters nº15).
- Lightly lubricate the movement zone of the lock (Caution: the
electrical area should not be lubricated).
- If the problem persists replace the electrical lock with a new one.
- Decrease the impact sensitivity value (parameter 45)
E9
A short sound
every 30
seconds
Battery in
poor
condition
- Check the battery is connected to the unit control.
- If the problem persists the battery is discharged and should be
left to charge for at least 15 minutes. For this it will only be
necessary to plug the Control Unit into the electricity supply.
- If the problem persists then replace the battery by a new one.
E10
_ _ _ _ _ _ _ _
_ _ __
Error in the
motor
- The motor is in bad condition or the operator is too inclined or
uneven.
E11
_ _ _ _ _ _ _ _
_ _ _ __
Erroneous
position
- Check that the cabling of the motor coder is correctly connected
and in good condition along the length of its run.
- Check that the arm of the mechanism is correctly fixed and