doesn’t have any space.
E12
_ _ _ _ _ _ _ _
_ _ _ _ __
Error in the
supervision
of the
internal
sensor
movement
(internal
sensor)
- Check that the internal movement sensor connected has the
supervision option activated (Monitoring).
- Check that the movement sensor is correctly connected.
-If the problem persists, replace the movement sensor with a new
one.
14.1 Trouble Shooting
Problem
Solution
The POWER symbol on the
LED display does not light
up.
- There is a fault in the supply or the Control Unit to the electricity
supply (110-230Vac).
- Turn off the Control Unit. After some seconds have gone past,
connect the Control Unit up again.
- If the problem persists, replace the Control Unit by a new one.
The INPUT ON signal does
not light up on the display
when the sensor is
activated.
- Check that the function selector is correctly connected and is
working correctly.
- Check that the function
selector is not in the position of “Door
closed” or “Manual Door”.
- Check that the sensors are correctly connected. It could be that
one of the components connected to the control unit is creating a
short circuit due to a bad connection. Check the 24Vdc in
connector P2.
- If the problem persists, replace the Control Unit by a new one.
The door doesn’t close or
open completely and there
are some centimeters
required to complete the
operation.
- Check that there is no friction in the movement.
- Check that the arm is working correctly to the end.
- If the problem persists, increase the even closing and opening
motor after the brake (Parameter 28 and 29) until the problem is
resolved.