Electronic control Fault description 53 - 79
19
53 CUT.IN G1>G2
Switching from main to sub generator taking
too long.
Contact Micon.
54 CUT.IN ERROR
Engaging takes too long when motor started.
55 REPEATING ERROR
At least one fault has activated more than
once, within one hour.
56 CURR. OVERL. BREAKER
No signal on teminal 16
57 TIP BRAKE OVERPRES.
No signal on teminal 34 for 1 sec.
Autoreset when RPM on Gen. = 0
58 TIP BRAKE LOW PRESS.
If the parameter time for hydraulic pump of
the tip brake is exceeded.
59 COOLING WATER LEVEL
No signal on terminal 20
60-75 ??????????????
76 TEMP. 7 OUTDOOR
Temperature is outside the parameter values
in 60 sec.
Autoreset when the temp. has been within the
alarm point for 60 minutes
77 TEMP. 8 MAIN BOARD
Temperature is higher than parameter value
in 60 sec.
Autoreset when the temp. has been below the
alarm point for 60 minutes.
78 TEMP. 9 NACELLE
Temperature is higher than parameter value
in 60 sec.
Autoreset when the temp. has been below the
alarm point for 60 minutes.
79 TEMP.10 WATER FORWARD
Temperature is higher than parameter value
in 60 sec.
Autoreset when the temp. has been below the
alarm point for 60 minutes.