Micon M1500-600/150kW 50Hz
Manual
UK1500.PM6
Rev. 95-06-23 OKK
3
Electronic control
NO. TEXT
CAUSE
ALARM DELAY (S)
RESET LEVEL
MAX ERROR/HOUR
YAWING
ALARM
+
= Activates a response
/
= No response
-
= Prevents a response
M
= Manual control from the mill
F
= Remote control via management system
A
= Automatic
P
= Parameter
Fault code table
21
- running free + P > XX KW
prog. run-through > 0.03
TERM (01) = 0 / TERM (29) = 0
Curr. phase sequence deviating
P > MAX
Gen. RPM. > 400 - BRAKE_ACTIVE
no change in wind direction.
TERM (07) = TERM(08) + YAWING
TERM (19) = 0
TERM (12) = 0 + BYPASS 3 sec.
Phase current deviation
Temp._1> XXX°
Temp._2> XXX°
Temp._3> XXX°
Temp._4> XXX°
Temp._5> XXX°
Temp._6> XXX°
Term.(28)=0
22
AWAIT START WIND
23
PROGRAM CONTROL
24
G2 HOT
25
R-S-T 120°
26
OVERPRODUCTION
27
LONG BRAKE TIME
28
WIND VANE DEF.
29
YAW SENSOR DEF.
30
HYD.PRESS.ERROR
31
?????????????
32
BYPASS MISSING
33
CURRENT ASSYMET.
34
TEMP. 1 WATER RETURN
35
?????????????
36
GEAR OIL HOT
37
TEMP. 3
38
?????????????
39
TEMP. 4 GEN. 1
40
TEMP. 5
41
TEMP. 6 GEAR OIL
42
LIGHTNING PROT
0
0,02
10
10
10
00-99
0-999M
75
1
0.8
1
60
60
60
60
60
60
0,1
/
/
+
/
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
/
/
+
+
+
+
+
-
+
+
+
+
+
+
+
+
+
+
+
+
+
/
3
1
1
1
/
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
A
A
A
A
A
M
A
A
F
F
A
A
A
F
A
A
F
A
A
A
F