Micon M1500-600/150kW 50Hz
Manual
UK1500.PM6
Rev. 95-06-23 OKK
Service intervals
4.1
SERVICE IS DIVIDED INTO THE FOLLOWING
PERIODS:
A: First service inspection
B: Bi-annual service inspection
C: Annual service Inspection
D: 2 Years service inspection
E: 5 Years service inspection
A: First service inspection
The first service inspection must take place 1-3
months after the mill has started running
automatically. At this inspection, particular
attention is paid to the tightening-up of all bolts
by 100%, a full greasing and filtering of gear oil..
B: Bi-annual service inspection
Regular service inspections commence 6 months
after the first.
The bi-annual inspection consists of lubrication
and a safety test of the mill.
C: Annual service inspection
The yearly service inspection consists of a bi-
annual inspection, plus a full component check
(See table).
Bolts are checked with a torque wrench.
The check covers 10% of every bolt assembly; at
least two bolts are marked, to ensure that the
same bolts are not unnecessarily checked next
time.
If any bolts are found to be loose, all bolts in that
assembly are tightened 100% and the event
logged.
4
Maintenance
24
D: 2 years service inspection
The 2 years service inspection consists of the
annual inspection, plus checking and tightening
of terminal connections.
E: 5 years service inspection
The 5 years inspection consists of the annual
inspection, an extensive inspection of the wing
braking system, checking and testing of oil and
grease, balance check and tightness of terminal
connectors.