background image

Bio-sensing radar

60GMilimeterwave

MicRadar Technology (Shenzhen) Co. ,LTD

R60AFD1-Fall detection module using guide

Please read the product instructions carefully before use and
keep them properlyV1.0

Summary of Contents for R60AFD1

Page 1: ...Bio sensing radar 60GMilimeterwave MicRadar Technology Shenzhen Co LTD R60AFD1 Fall detection module using guide Please read the product instructions carefully before use and keep them properlyV1 0 ...

Page 2: ... kitchen and bathroom The fall still dwell function detection is not affected by factors such as temperature humidity noise airflow dust light and complete stillness of the human body 2 Appearance introduction 3 Main performance description 3 1 Main functions of radar function points State change time function explanation DP1 Someone Nobody No one to someone report within 0 5s From someone to no o...

Page 3: ... GND land 3 SL reserve 4 SD reserve 5 GP 3 Spare expansion pins 6 GP 4 Spare expansion pins 7 GP 5 Spare expansion pins 8 GP 6 Spare expansion pins Pin Description DP5 Stationary park alarm Report static parking alarm when it is stationary for 5 minutes DP6 Installation height setting The default setting is 240 cm and it can be set to 200 cm 300 cm DP7 Fall alarm switch Control whether the fall al...

Page 4: ...n control terminals which can be redefined according to user needs 2 The output signals of this interface are all 3 3V level Use wiring diagrams Module wiring diagram 5 Tool preparation 5 1 TTL serial port tool DuPont line PC computer serial port assistant terminal 5 2 Radar EVB demo board default Tuya platform you can freely adapt your own communication module 5 3 Radar User Manual Protocol 6 Pow...

Page 5: ... it on the top radar is installed vertically and the horizontal deviation angle is 5 to ensure that the main beam of the radar covers the detection area the recommended installation height of the radar is 2 meters H 3 meters there are no obvious obstructions and coverings in front of the radar Affected by the installation height of the radar and the range of the radar beam in this installation mod...

Page 6: ...al installation method of the radar and select the installation angle setting according to the specific installation method the installation method is top mounted Step 4 Determine the entrance and exit of the space and point the long side of the radar to the entrance and exit to ensure the trigger effect of people entering Step 5 Confirm whether there is an interference source within the radar det...

Page 7: ...ide faces the door 9 Layout Requirements for Antenna and Housing PCBA Need to keep the height of the radar patch 1mm than other devices 3 mm between the radar antenna surface and the housing surface Shell detection surface non metallic shell need to be straight avoid curved surface affect the performance of the entire scanning area 10 Common problem Interference factors Radar is an electromagnetic...

Page 8: ... clothing curtains thin wood and glass The installation angle and performance of the radar need to be determined according to the application Semi interference factor Radar judges the existence of human body and is not suitable for directly facing the air conditioner The motor inside the air conditioner can cause the radar to misjudge It is required that the radar product does not directly face th...

Reviews: