COMPRESSED AIR INSTALLATION:
The compressed air inlet for the Roto-Pulse cleaning
system is at the top of the surge tank located on the side of
the unit (Figure 15). A minimum of a 3/4 inch diameter
line and
clean, dry compressed air at a pressure of 80 psi
to 90 psi is required
for proper operation of the Roto-pulse
cleaning system. For models FRP8-3 and FRP8-4 two 3/4
inch diameter lines from a minimum 1 inch diameter header
line are required. A unit specifi c combination regulator/
fi lter dryer is highly recommended for proper operation.
ELECTRICAL INSTALATION:
Caution: Installation can cause
exposure to live components. Disconnect
electrical power before proceeding with
installation. Proper lock out/tag out
procedures should be used.
PULSE CONTROLS ONLY ELECTRICAL BOX
1. Open the electrical box cover located on the side of the
unit. Make connections from your 120V supply power
to terminal L, N and G (Figure 16).
2. When supply power has been terminated, reconnect
the power. Momentarily turn the motor blower on and
adjust pressure switch via set screw until contact is
made. Use an ohm meter to measure continuity across
the pressure switch.
FULL CONTROL ELECTRICAL BOX
1. Determine the location for mounting the electrical box
(on the unit or remotely). If mounting is on the unit
mount near the pulse jumper box in order to minimize
electrical runs if feasible.
2. Mount the electrical box.
3. Open the electrical box cover located on the side of
the unit. Make connections from your 208V, 230V, or
460V supply power to power distribution terminal L1,
L2, and L3 (Figure 17). Wire size should be rated for
FLA of your application.
10
FIGURE 15
Compressed Air Inlet
3/4” Female NPT
!
Set Screw
Power Connection
Pressure Switch
Timer Board
FIGURE 16
FIGURE 17
Timer Board
Overload
Power Distribution
Terminal
Contactor
Summary of Contents for FORCE FRP4
Page 13: ...FRP MICRO AIR CLEAN AIR SYSTEMS 13 FRP4 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 14: ...14 MICRO AIR FRP CLEAN AIR SYSTEMS FRP6 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 15: ...15 FRP MICRO AIR CLEAN AIR SYSTEMS FRP8 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 16: ...16 MICRO AIR FRP CLEAN AIR SYSTEMS FRP6 2 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 17: ...17 FRP MICRO AIR CLEAN AIR SYSTEMS FRP6 3 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 18: ...18 MICRO AIR FRP CLEAN AIR SYSTEMS FRP8 2 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 19: ...19 FRP MICRO AIR CLEAN AIR SYSTEMS FRP8 3 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 20: ...20 MICRO AIR FRP CLEAN AIR SYSTEMS FRP8 4 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 21: ...21 FRP MICRO AIR CLEAN AIR SYSTEMS FRP4 FULL CONTROL WIRING DIAGRAM ...
Page 22: ...22 MICRO AIR FRP CLEAN AIR SYSTEMS FRP6 FULL CONTROL WIRING DIAGRAM ...
Page 23: ...23 FRP MICRO AIR CLEAN AIR SYSTEMS FRP8 FULL CONTROL WIRING DIAGRAM ...
Page 24: ...24 MICRO AIR FRP CLEAN AIR SYSTEMS FRP6 2 FULL CONTROL WIRING DIAGRAM ...
Page 25: ...25 FRP MICRO AIR CLEAN AIR SYSTEMS FRP6 3 FULL CONTROL WIRING DIAGRAM ...
Page 26: ...26 MICRO AIR FRP CLEAN AIR SYSTEMS FRP8 2 FULL CONTROL WIRING DIAGRAM ...
Page 27: ...27 FRP MICRO AIR CLEAN AIR SYSTEMS FRP8 3 FULL CONTROL WIRING DIAGRAM ...
Page 28: ...28 MICRO AIR FRP CLEAN AIR SYSTEMS FRP8 4 FULL CONTROL WIRING DIAGRAM ...
Page 32: ...32 MICRO AIR FRP CLEAN AIR SYSTEMS THIS PAGE INTENTIONALLY LEFT BLANK ...