MICRO AIR
®
FRP
CLEAN AIR SYSTEMS
4. When supplied, bolt on angle braces with provided
hardware (Figure 5). Ensure each leg is plumb before
tightening the bolts.
5. When the legs and angle braces have been completely
installed each leg should be anchored to the ground
using all the provided holes in the base plates (1/2” dia.
anchors are recommended).
6. Install provided hole plugs into unused bolt holes in
legs
Caution: The unit is not designed to
be operated while hanging from lifting
brackets. Unit must be mounted on legs
and cross bracing installed when supplied.
7. FRP4, FRP6 and FRP8 require installation of the top
inlet plenum as shown in FIG. 6.
a. Apply self-adheasive foam on the bolt hole fl ange
of the inlet plenum.
b. Place inlet plenum on top of dust collector and
align the bolt holes.
c. Attach the inlet plenum using 14 ea. 5/16” bolts,
washers and lock washers.
d. Three cap plates can be removed and reinstalled to
allow you to use the opening best suited for your
installation.
6
FIGURE 5
!
FIGURE 6
Self-Adheasive
Foam
Lock Washer
Flat Washer
Hex Bolt
Top Inlet Plenum
ANCHOR DETAIL
Anchor should project
a minimum of 1 3/4-in
and account for nut,
washer, base plate and
shims.
Embedment depth,
6” minimum.
Summary of Contents for FORCE FRP4
Page 13: ...FRP MICRO AIR CLEAN AIR SYSTEMS 13 FRP4 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 14: ...14 MICRO AIR FRP CLEAN AIR SYSTEMS FRP6 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 15: ...15 FRP MICRO AIR CLEAN AIR SYSTEMS FRP8 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 16: ...16 MICRO AIR FRP CLEAN AIR SYSTEMS FRP6 2 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 17: ...17 FRP MICRO AIR CLEAN AIR SYSTEMS FRP6 3 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 18: ...18 MICRO AIR FRP CLEAN AIR SYSTEMS FRP8 2 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 19: ...19 FRP MICRO AIR CLEAN AIR SYSTEMS FRP8 3 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 20: ...20 MICRO AIR FRP CLEAN AIR SYSTEMS FRP8 4 PULSE CONTROL ONLY WIRING DIAGRAM ...
Page 21: ...21 FRP MICRO AIR CLEAN AIR SYSTEMS FRP4 FULL CONTROL WIRING DIAGRAM ...
Page 22: ...22 MICRO AIR FRP CLEAN AIR SYSTEMS FRP6 FULL CONTROL WIRING DIAGRAM ...
Page 23: ...23 FRP MICRO AIR CLEAN AIR SYSTEMS FRP8 FULL CONTROL WIRING DIAGRAM ...
Page 24: ...24 MICRO AIR FRP CLEAN AIR SYSTEMS FRP6 2 FULL CONTROL WIRING DIAGRAM ...
Page 25: ...25 FRP MICRO AIR CLEAN AIR SYSTEMS FRP6 3 FULL CONTROL WIRING DIAGRAM ...
Page 26: ...26 MICRO AIR FRP CLEAN AIR SYSTEMS FRP8 2 FULL CONTROL WIRING DIAGRAM ...
Page 27: ...27 FRP MICRO AIR CLEAN AIR SYSTEMS FRP8 3 FULL CONTROL WIRING DIAGRAM ...
Page 28: ...28 MICRO AIR FRP CLEAN AIR SYSTEMS FRP8 4 FULL CONTROL WIRING DIAGRAM ...
Page 32: ...32 MICRO AIR FRP CLEAN AIR SYSTEMS THIS PAGE INTENTIONALLY LEFT BLANK ...