3
MAE2200
®
NOTE:
During the step, it is recommended that two people be
used: one to support the arm assembly, while the other
attaches hardware to clamp arm assembly onto base collar.
2.
Once the arm assembly is attached to the base collar,
raise the arm to a horizontal position (arm parallel to floor).
Using the hardware provided, attach the rigid pipe section
as shown in
FIG. 3
.
3.
If vertical adjustment of the arm is required, adjustment
can be made by repositioning the clamp band along the
pipe section.
4.
To reposition the clamp band, loosen the 1/4" bolts on
clamp band so that the clamp band can be moved for arm
adjustment.
NOTE:
This is for fixed arm models only. If your arm has a
linear actuator proceed to Step 5.
5.
For models that use a motorized base joint, assemble the
linear actuator to the base collar with hardware provided.
Then assemble other end to the clamp band, similar to
that of the fixed joint assembly. (See
FIG. 4
.)
WARNING: FOR MODELS WITH A LINEAR ACTUATOR
DO NOT RELOCATE CLAMP BAND IN SUCH A WAY THAT
LINEAR ACTUATOR COULD COME IN CONTACT WITH
MAE2200 PLENUM OR OTHER OBJECT WHEN
ACTUATOR IS FULLY RETRACTED.
ELECTRICAL INSTALLATION
CAUTION: INSTALLATION CAN CAUSE EXPOSURE TO
LIVE COMPONENTS. DISCONNECT ELECTRICAL POWER
BEFORE PROCEEDING WITH INSTALLATION.
1.
LINEAR ACTUATOR INSTALLATION:
The linear actuator is supplied with a 3-conductor input
power cable and a phone-type control cable.
A.
The input power cable is supplied with a 3-pin
quick-connect plug which plugs into the 3-pin
receptacle located below the electrical box.
B.
The phone-type control cable is supplied with
two plugs that plug into the actuator on one end
and a phone jack receptacle located below the
electrical box.
2.
LOW VOLTAGE CONTROL CABLE:
The low voltage control cable is a seven-conductor cable that
once connected allows the control switches located at the
nozzle to control the linear actuator, lamp, and motor/blower.
Connect the control cable to the 9-pin connector in the
electrical box bottom.
NOTE:
When a single arm configuration is used, be certain to
connect all power and control cables to their respective
receptacles labeled ARM #1. (See
FIG. 5
.)
3.
The MAE2200 is designed to operate from 208-230/460
VAC at 60 Hz, 3-phase. Takes input power cable through
the knockout hole in the power box bottom and connect
input power wiring to the designated wiring terminal strip.
Be sure to ground AC input per local electrical codes.
FIG. 5
NOTE:
Once the input voltage is supplied to the electrical box,
control transformers become energized. It is recommended
that a disconnect switch or breaker box be installed in line with
the system to remove input power from system when not in
use.
BASE JOINT
ATTACH RIGID PIPE SECTION
TO SWIVEL BASE USING THE
CLEVIS PIN PROVIDED
1/4" - 20 HEX BOLT, FLAT
WASHER, 1/4" - 20 HEX NUT (2) PLCS.
CLAMP BAND
20° REFERENCE
ACTUATOR COMPLETELY
RETRACTED
CLEVIS PIN
FLAT WASHER
COTTER PIN
1/4" - 20 HEX BOLT, FLAT WASHER
1/4" 20 NUT (2) PLCS.
CLAMP BAND
TYP. CLEVIS PIN
CONFIGURATION
FIG.4
FIG.4