FILLING OF RCM MODULES
1. Remove bulk charcoal or purasorb from shipping carton by removing plastic bags within carton.
2. set module on level surface. Remove fill cover by removing six 10-32 phillip head screws, that secure cover. Set cover aside
(See
FIG. 6
).
3. Open the plastic bag by removing the tape, holding close. Pour the material from the plastic bag into the module through the
slots. It may be necessary to slightly shake the module to assure an even fill. Excess material may be saved by resealing the
plastic bag.
NOTE:
Slow pouring will minimize dust that will be present during pouring.
4. After filling module, discard plastic bag and reinstall fill cover removed in step 2.
NOTE:
The MX3510 requires two modules when used as a second main filter and four modules when used as a first and second
main filter.
5. With Filter track in place and handle pulled out away from cabinet load RCM / HEPA modules into track.
NOTE:
Make sure modules are seated properly into track and stacked evenly.
6. With filters in place rotate handle 90° and lock filter modules in place.
POUR MATERIAL
INTO SLOTS
FILL COVER
FIG. 6